Condec DLR334 User Manual
Page 13
![background image](/manuals/361800/13/background.png)
PAGE 13
74845
02
3
07
8
12
16
17
35
03
4
08
9
13
18
18
40
04
5
09
10
14
20
19
45
EXAMPLE: A filter setting of 14 would be *FLE{11}
14.5 PORT 1 SERIAL SETUP:
Not supported at this time.
14.6 PORT 2 SERIAL SETUP:
COMMAND:
P2E/P2R
DATA FORMAT:
|
LENGTH:
Fixed at 15 characters.
WHERE:
(all codes fixed at one (1) number code; see code tables below)
mode
= Format mode select.
del
= Delay select.
t&d
= Time and Date.
data
= Data select.
eol
= End of line terminator.
sol
= Start of text character.
eot
= End of text character.
CODE # PORT 2 PARAMETER ASSIGNMENT
CODE# MODE
DELAY
T & D
DATA
EOL
SOT
EOT
0
STD
AUTO
OFF
DISP
CR/LF
STX
NONE
1
MOD
1 SEC
ON
GTN
CR
NONE
EOT
2
CUST
2 SEC
ABOVE
SOH
ETX
3
3 SEC
BELOW
FF
4
4 SEC
LF
5
5 SEC
14.7 INPUT SETUP:
COMMAND:
INE/INR
DATA FORMAT:
LENGTH:
Fixed at 3 characters.
WHERE:
(all codes fixed at one (1) number code; see code table below)
I1
= Input #1
I2
= Input #2
CODE # INPUT 1 and 2
PARAMETER ASSIGNMENT
CODE#
MODE
0
OFF
1
Freeze
2
Zero
3
Tare
4