Specifications – STI HK3 User Manual
Page 3
![background image](/manuals/361277/3/background.png)
3
Polycarbonate Cleaning Instructions
Rinse with water to remove abrasive dust and dirt. Wash with soap or mild detergent, using a soft cloth.
Rinse once more, then dry with a soft cloth or chamois. Exercise caution when using water inside enclo-
sure. Make sure unit is completely dry inside before reassembling. Do not use razor blades.
Specifications
Polycarbonate Enclosure
Flammability
UL94 V-2
Wall Thickness
back box: .20 inches (5.1mm)
cover: .12 inches (3.1mm)
NEMA Rating
3R
Warranty
Lifetime against breakage in
normal use.
Silicone Laminate Heater
STI-1200A-HTR 110 VAC 50/60 Hz
UL Recognized Component
STI-1200-A-HTR240 240 VAC 50/60 Hz UL Recognized Component
100 Watts
Life: @ -10˚C (14˚F) ~ 70˚C (158˚F)
5 Years
Duty Cycle: -40˚F (-40˚C)
16%
-70˚F (-57˚C)
38%
-99˚F (-73˚C)
100%
Fan
24 VDC (±10%), 90 mA
UL Recognized Component
Life
5 Years Continuous Duty
WARNING: The polarity of the circulating fan is important as it only
rotates in one direction with red lead being positive.
MISE EN GARDE: La polarité du ventilateur de circulation est importante car
il ne tourne que dans un sens avec son fil rouge étant celui du pôle positif.
Gasket
Material
Neoprene
Life
5 Years
PART #
HEIGHT
WIDTH
DEPTH
Internal Dimensions
(158mm)
(104mm)
(31mm)
1200A-HTR
6.25 in.
4.125 in.
1.25 in.
1200A-HTR240