INSTALLATION OF STI SUB-315, SUB-316 VENTILATION KITS
All specifications and information shown were current as of publication and are subject to change without notice.
31516IS JAN97
SUB-316 ALUMINUM LOUVER
(2) PROVIDED
STI RECOMMENDS THE APPLICATION
OF A GOOD ADHESIVE (LOCTITE 414) OR
SIMILAR INSTANT ADHESIVE APPLIED TO
UNDERSIDE OF LOUVER FLANGE AS SHOWN
FLAT BOSSES MUST FACE UPWARD AS SHOWN
SUB-315 STAINLESS STEEL GRILL,
SLIDE INTO LOWER CONDUIT NOTCH
PRIOR TO INSTALLATION OF LOUVERS
ROTATE LOUVER FINS TO A DOWNWARD
POSITION AS SHOWN
DRILL 2 1 in.(25mm) DIAMETER HOLES
BOTH SIDES AS SHOWN
BEST RESULTS ARE OBTAINED USING A HOLE
SAW TURNED AT 200-300 RPM’S WITH SLOW FEED RATE
NOTE: IF CLEARANCE FOR ELECTRICAL CONDUIT
IS NOT NEEDED STI RECOMMENDS THE (2) KNOCK OUTS
BE PLACED IN NOTCHES AS SHOWN
1 in.(
25m
m)