Stuart Turner Techflo TP 60TNH User Manual

Page 8

background image

- 8 -

Cont ...

2.32

Non-preferred pump location: If it is not possible to locate the pump in the

preferred area due to site limitations and it is necessary to position the unit in the

loft, or in a position above the secondary tapping that feeds the pump, then there

is an increased risk of air locks. This risk must be eliminated.

The following measure is a suggestion that may overcome the problem:

In this application only use an Essex or Techflow side entry flange, then fit a “U”

bend or downward loop in the supply pipe to the pump of 350 mm depth before

rising to the pump should ensure the cylinder vents its air up the expansion pipe,

not up the pump feed (Figs. 6 & 7).

Max. inlet head

6

m

Min. inlet head

0.5

m

hot water
services

Negative

head

200

mm

min

350

mm

Max. outlet head

6

m

least preferred area

Fig. 7 - Twin Pump

Max. inlet head

6

m

Min. inlet head

0.5

m

Negative

head

200

mm min

350

mm

min

Max. outlet head

6

m

least preferred

area

Fig. 6 - Single Pump