beautypg.com

Stuart Turner Techflo TP 60TNH User Manual

Page 7

background image

- 7 -

Cont ...

Hot water connection:
2.28

Hot water cylinder or storage tank: When a hot water cylinder or storage tank

is used, ensure the pipework size from the cold water storage to the hot water

storage is of adequate size and a minimum of 22 mm.

2.29

Hot water supply: The pump must be supplied with a dedicated feed direct

from the hot water cylinder or storage tank, ensuring an air free connection to the

cylinder, which can be made by one of the methods shown in Fig. 5. We

recommend the use of the Techflow top flange Part No 27901.

2.30

Expansion pipe: When the method of connection is to be made via the

expansion pipe, the

BASE of the cold water storage tank MUST be at least

1 metre above the connection/take off of the hot water storage cylinder feeding

the

pump.

2.31

Location: The pump must, for optimum performance, be sited as close as

possible to and never more than 4 metres from the HOT WATER cylinder. The

pump should always be sited BELOW the HOT WATER take-off from the cylinder.

Fig. 5

(a) G 1 Techflange
(Part No. 27901)
with 22 mm
pipework to pump.

(b) Off expansion
pipe with rising
22 mm offset and
22 mm pipework
to pump.

(c) Off vertical
expansion pipe
with 22 mm
pipework to pump.

or

Site installed G 1
tank flange with
22 mm pipework to
pump.

(d) Factory installed G ¾
secondary tapping
with 22 mm pipework
to pump.

or

Side mounted
Techflange with 22 mm
pipework to pump.