Stuart Turner WC1 Toilet only Macerator User Manual
Page 4
- 4 -
Cont ...
ACCESSORIES CHECKLIST
1 LOCATION
1.11 The unit must be connected directly to the outlet spigot of the WC pan. Allow a
minimum height of 220 mm above the unit, for maintenance and servicing.
1.12 The unit must be positioned away from heat sources, such as radiators and
heaters.
1.13 Care must be taken to protect the unit against frost and freezing. All pipes at risk
of freezing must be protected by thermal insulation.
1.14 The unit must be located immediately behind the WC pan and
must not be
mounted behind a partition wall.
IMPORTANT: With the product
removed from its packaging check
for any damage prior to installation.
If any damage is found contact Stuart
Turner Ltd within 24 hours of receipt.