Stuart Turner WC1 Toilet only Macerator User Manual

Page 4

background image

- 4 -

Cont ...

ACCESSORIES CHECKLIST

1 LOCATION

1.11 The unit must be connected directly to the outlet spigot of the WC pan. Allow a

minimum height of 220 mm above the unit, for maintenance and servicing.

1.12 The unit must be positioned away from heat sources, such as radiators and

heaters.
1.13 Care must be taken to protect the unit against frost and freezing. All pipes at risk

of freezing must be protected by thermal insulation.

1.14 The unit must be located immediately behind the WC pan and

must not be

mounted behind a partition wall.

IMPORTANT: With the product
removed from its packaging check
for any damage prior to installation.
If any damage is found contact Stuart
Turner Ltd within 24 hours of receipt.

Qty 1

Qty 1

Qty 3

Qty 1 (WC2)
Qty 2 (WC3)

Qty 1

WC Connector

Inlet Connector

Non-Return Valve
Assy

22, 28, 32 mm
Adaptor

Adjustable
Clips

Qty 1 (WC2)
Qty 2 (WC3)

Reducing ring to
suit 32 mm (1¼ ")
diameter pipe

A

B

C

D

E

F