6 MAINTENANCE

6.11 Turn off water supplies to the pump and release pressure by

opening water outlets before attempting maintenance.

6.12

Pressure vessel: Should ever the need arise for the vessel to have its air

charge checked or replenished, it should be carried out as follows: -

a)

Isolate

pump

electrically.

b) Isolate hot and cold water supplies via the integral pump isolating valve

located in the flexible hoses (see Section 3 - Pump Connections).

c) Release system water pressure by opening a system outlet (tap).

d) Check air charge at Schrader valve (Fig. 17) using a tyre pressure gauge.

Model

Vessel Pressure

kPa

bar

psi

All Models

150

1.5

21.75

Fig. 17

Pressure vessel

Schrader valve

Single pump shown

e) Replenish air charge if required by injecting air into the vessel via the

Schrader valve using a car or bicycle pump, ensuring a system outlet valve

(tap) remains open during this procedure to allow the vessel to exhaust any

excess

water.

f) Close all system taps, open hot and cold inlet pump isolating valves, turn on

electrical

power.

g) After maintenance is completed refer to Section 5 - Commissioning for

instructions on re-starting pump.

This manual is related to the following products: