Cable Gland Fitting Instructions:

To enable correct assembly of the cable gland the ‘O’-ring (Fig. 16 item 1) must

be placed over the cable before the clamping insert (Fig. 16 item 2) can be

tightened.

Note: Cable diameter range:- 6.5 mm to 9.5 mm.

4.25

Supply Cord Extension:

The pumps are fitted with a supply cord to the following specification:-

All models . . . . . . . . . . . . . . . . . HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.

If the supply cord is to be extended, a cord of the same specification should be

used. Any connections or junction boxes used should be specifically suited for

the application and installed in accordance with the manufacturers instructions.