Cold water connection:
2.27

The cold water supply: The supply must be air free and have a dedicated

connection to the tank which should be via a tank connector, positioned at a

slightly lower level (25 mm minimum) than the feed pipe to the hot water cylinder.

Do not connect to the mains.

2.28

Location: The pump must, for optimum performance, be sited as close as

possible to and never more than 4 metres from the HOT WATER cylinder. The

pump should always be sited BELOW the HOT WATER take-off from the cylinder.

Hot water connection:
(Applicable to U1.5, U2.0, U3.0 and U4.0 bar Twins)
2.29

Hot water cylinder or storage tank: When a hot water cylinder or storage tank

is used, ensure the pipework size from the cold water storage to the hot water

storage is of adequate size and a minimum of 22 mm. The U4.5 bar Twin should

have pipework of a minimum of 28 mm.

2.30

Hot water supply: The pump must be supplied with a dedicated feed direct from

the hot water cylinder or storage tank. We recommend the use of the Stuart top

flange Part No 27800 (for all models except the U4.5 bar Twin).

2.31 The supply must be air free and connection to the cylinder can be made by one of

the methods shown in Fig. 5 (S4.5 bar Twin should only use ‘a’ or ‘d’).

2.32

Expansion pipe: When the method of connection is to be made via the

expansion pipe, the cold water storage cistern should be at least 1 metre above

the top of the hot water cylinder.

Fig. 5

Off expansion
pipe with rising
28 mm offset
reducing to
22 mm pipework
to pump and
expansion pipe.

Off expansion
pipe with rising
22 mm offset
and 22 mm
pipework to
pump.

G 1 Stuart flange
(Part No. 27800)
with 22 mm
pipework to pump.

Factory installed G ¾
secondary tapping with
22 mm pipework to
pump.

or

Side mounted
Techflange with 22 mm
pipework to pump

a

b

c

d