To enable correct assembly of the cable gland the ‘O’-ring (Fig. 12 item 1) must

be placed over the cable before the clamping insert (Fig. 12 item 2) can

be

tightened.

Note: Cable diameter range:- 6.5 mm to 9.5 mm.

4.25

Supply Cord Extension:

The pumps are fitted with a supply cord to the following specification:-

All models . . . . . . . . . . . . . . . . . HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.

If the supply cord is to be extended, a cord of the same specification should be

used. Any connections or junction boxes used should be specifically suited for

the application and installed in accordance with the manufacturers instructions.

4.24

Cable Gland Fitting Instructions: