List of parameters, 2 event output setting – Yokogawa Data Acquisition with PID Control CX2000 User Manual
Page 11
11
IM 04L31A01-05E
List of Parameters
List of Parameters are given in the
DAQSTATION CX2000 Operation Guide (IM04L31A01-02E)
or the
DAQSTATION CX1000 Operation Guide (IM04L31A01-04E)
.
With the functional changes, the parameters below (underlined sections) have been changed.
Basic Setting Mode
CX2000: #9 AUX, Time zone
CX1000: #12 AUX, Time zone
Chinese has been added to AUX > Language.
Parameter
Selectable Range or Selections
Initial Value
AUX > Tag/Channel
Tag/Channel
Tag
AUX > Memory alarm
Off, 1h, 2h, 5h, 10h, 20h, 50h, or 100h
1h
AUX > Language
English, Japanese, German, French, or Chinese
English
AUX > Partial
Use/Not
Not
Time zone > Difference from GMT
–1200 to 1200
0
Batch
Use/Not
Use
CX2000: #10 Control <#2 DI/DO/SW-registration, AUX (Alarm mode...)>
CX1000: #12 Control <#4 AUX (Alarm mode...)>
AUX > Event output setting has been added.
Parameter
Selectable Range or Selections
Initial Value
AUX > Loop number
1 to 6
1
AUX > Remote setting
Off or Remote
Off
AUX > Alarm mode
ALWAYS, STOP, or STOP/MAN
ALWAYS
AUX > SP No. selection source 1 to 6
On/Off
1: On, 2-6: Off
AUX > PV/SP math
On/Off
Off
AUX > CLOG error
Error, Skip
Error
AUX > Event output setting
Common/Separate
Common
Setting mode (Control)
#7 Program control related (only when program control is ON)
“#6 Event output setting” in “Program parameter setting” is no longer available. <#2 Event output setting> is
displayed directly under “#7 Program control related.” As a result, “AUX (Auto message, Display position)” directly
under “#7 Program control related” is displayed as #3 and “AUX (Event group)” is displayed as #4. In addition,
“Hysteresis (PV event)” in <#1 Program parameter setting> is displayed as #6 and “Repeat action setting” is
displayed as #7.
<#2 Event output setting>
Parameter
Selectable Range or Selections
Initial Value
Event output > Pattern number
1 to 4 (/PG1), 1 to 30 (/PG2)
1
(only when the event output setting in Basic
Control Settings is set to Separate)
Event output > Event kind
PVEvent, TimeEvent TimeEvent
Event output > Relay Output EV1 to 16
On/Off
Off
Event output > On EV1 to 16 > Number
DO001 to DO006, DO101 to DO106,
DO001
DO201 to DO206, RO001 to RO012,
SW001 to SW036
Program pattern end signal > Relay Output
On/Off
Off
Program pattern end signal > On > Number
DO001 to DO006, DO101 to DO106,
DO001
DO201 to DO206, RO001 to RO012,
SW001 to SW036