3

2. LOG

Input

Specifications

2.1. Converting the LOG Input (Relationship between the Input Voltage and Digital

Display)

Trend display (logarithmic scale): Displays the input voltage on a logarithmic

scale.

Digital display:

Displays the result obtained by converting the
input voltage using the equation below.

¾

The relationship between the input voltage of special LOG range and digital

display value is shown below.

Input voltage

X

Lower limit of display span VL

Upper limit of display span

VU

Scale lower limit

SL

Scale upper limit

SU

VL Input

X

VU

T


U

1.0E

SL

Y

1.0E

SU


Digital display value Y = 10

(SU-SL)*(X-VL)/(VU-VL)+SL


This manual is related to the following products: