3 model and suffix codes, 4 options, Model and suffix codes -2 – Yokogawa PK200 User Manual
Page 11: Options -2

IM 21B03D01-01E
2-2
2. OVERVIEW
TIIS Intrinsically Safe (/JS3):
Intrinsically Safe Ex ia IIC T4
Certificate: TC18266
Explosionproof Construction:
TIIS Explosionproof (/JF3): Flameproof Exd II
B+H
2
T6X
FM Explosionproof (/FF1): Explosionproof for Class
I, Division 1, Groups B, C and D.
Dust ignitionproof for Class II/III,
Division 1, Groups E, F and G.
Temperature Class: T6.
Outdoor hazardous locations, NEMA
4X.
Dustproof Construction: IEC IP54
Connections:
Air Connection: Rc1/4 or 1/4NPT female
Electrical Connection: G1/2, G3/4 female or
1/2NPT, 3/4NPT female
Mounting:
Vertical or horizontal 50mm (2-
INCH) pipe mounting
Wall mounting
Mass (weight):
2.8kg (6.1lb)
Accuracy:
±0.5% of span
Linearity:
±0.2% of span
Hysteresis:
0.2% of span
Repeatability: 0.1% of span
2.3 Model and Suffix Codes
PK200
Input Signal -A
4 to 20mA DC
-C
4 to 20mA/10 to 50mA DC selection type
Output Signal
1
Output signal Pa calibration
20 to 100kPa
scale 0 to 200kPa
2
Output signal Pa calibration
40 to 200kPa
scale 0 to 400kPa
3
Output signal kgf/cm
2
calibration 0.2 to 1.0 kgf/cm
2
scale 0 to 2kgf/cm
2
4
Output signal kgf/cm
2
calibration 0.4 to 2.0 kgf/cm
2
scale 0 to 4kgf/cm
2
5
Output signal bar calibration
0.2 to 1.0bar
scale 0 to 2bar
6
Output signal bar calibration
0.4 to 2.0bar
scale 0 to 4bar
7
Output signal P calibration
3 to 15psi
scale 0 to 30Psi
8
Output signal P calibration
6 to 30psi
scale 0 to 60Psi
9
Output signal P calibration
6 to 27psi
scale 0 to 60Psi
Connections
1
Air connection: Rc 1/4, Electrical connection: G1/2 female
2
Air connection: Rc 1/4, Electrical connection: G3/4 female
3
Air connection: 1/4 NPT female, Electrical connection: 1/2NPT female
4
Air connection: 1/4 NPT female, Electrical connection: 3/4NPT female
Option
/
See section 2.4.
Model
Suffix Code
Description
T0202.EPS
2.4 Options
• Option Code/JF3: JIS Flameproof
TIIS flameproof Exd II B+H
2
T6X
• Option Code/G11: Packing adapter for TIIS Flame-
proof
Electrical connection: G1/2 female, Applicable cable
O.D.: 8 to 12mm
• Option Code/G21: Packing adapter for TIIS Flame-
proof
Electrical connection: G3/4 female, Applicable cable
O.D.: 10 to 16mm
• Option Code/FF1: FM Explosionproof
• Option Code/JS3: TIIS Intrinsically Safe
Applicable only with input signal code-A.
• Option Code/CS1: CSA Intrinsically Safe
• Option Code/SCF-
ᮀ: Special Color Finished on
converter cover
Allows the paint color of only a converter cover to
be selectable by specifying the color in the specifi-
cation item with reference to GS22D1F1.
• Option Code/X1: Epoxy Paint
Epoxy resin-baked coating.
Not applicable for special color finished.