9 emc conformity standards, 10 pressure equipment directive (ped), Emc conformity standards -8 – Yokogawa EJX430B User Manual
Page 16: Pressure equipment directive (ped), Warning, Caution

<2. Handling Cautions>
2-8
IM 01C27B01-01EN
Note 4. Battery Pack
• Use only YOKOGAWA battery pack
F9915MA or F9915NS.
Note 5. Special conditions for Safe Use
• In case the enclosure of the Pressure
Transmitter is made of aluminum, if it
is mounted in an area where the use of
apparatus of equipment protection level Ga
is required, it must be installed such, that,
even in the event of rare incidents, ignition
sources due to impact and friction sparks are
excluded.
• For applications in explosive atmospheres
caused by gases, vapors or mists and
mounted in an area where the use of
apparatus of equipment protection level Ga
is required, electrostatic charges on the non-
metallic parts of the Pressure Transmitter
shall be avoided.
WARNING
• Potential electrostatic charging hazard -
secure distance of 100mm from antenna.
• Take care not to generate mechanical
sparking when access to the instrument and
peripheral devices in a hazardous location.
2.9 EMC Conformity Standards
EN61326-1 Class A, Table 2 (For use in
industrial locations), EN61326-2-3
CAUTION
This instrument is a Class A product, and it is
designed for use in the industrial environment.
Please use this instrument in the industrial
environment only.
2.10 Pressure Equipment
Directive (PED)
(1) General
• EJX Series pressure transmitters are
categorized as pressure accessories under
the vessel section of directive 97/23/EC, which
corresponds to Article 3, Paragraph 3 of PED,
denoted as Sound Engineering Practice (SEP).
• EJX110B-MS, EJX110B-HS,
EJX110B-VS, EJX510B-D, and
EJX530B-D can be used above 200 bar and
therefore considered as a part of a pressure
retaining vessel where category III, Module H
applies. These models with option code /PE3
conform to that category.
(2) Technical Data
• Models without /PE3
Article 3, Paragraph 3 of PED, denoted as
Sound Engineering Practice (SEP).
• Models with /PE3
Module: H
Type of Equipment: Pressure Accessory-Vessel
Type of fluid: Liquid and Gas
Group of fluid: 1 and 2
Model
Capsule
code
PS
(bar)*
1
V(L)
PS·V
(bar·L)
Category*
2
EJX110B
F, L
160
0.01
1.6
Article 3,
Paragraph 3
(SEP)
M, H, V
250
0.01
2.5
EJX110B
with code
/PE3
M, H, V
250
0.01
2.5
III
EJX310B L, M, A, B
160
0.01
1.6
Article 3,
Paragraph 3
(SEP)
EJX430B
H, A, B
160
0.01
1.6
Article 3,
Paragraph 3
(SEP)
EJX510B
A, B, C
100
0.1
10
Article 3,
Paragraph 3
(SEP)
D
700
0.1
70
EJX510B
with code
/PE3
D
700
0.1
70
III
EJX530B
A, B, C
100
0.1
10
Article 3,
Paragraph 3
(SEP)
D
700
0.1
70
EJX530B
with code
/PE3
D
700
0.1
70
III
*1: PS is maximum allowable pressure for vessel itself.
*2: Referred to Table 1 covered by ANNEX II of EC Directive