IM 01C21F01-01E

8-5

8. BRAIN TERMINAL BT200 OPERATION

T0806.EPS

Auxiliary setting data 1

D

Menu name

AUX SET 1

NORMAL/REVERSE
NORMAL/REVERSE*

4

Output reversal

D40 REV OUTPUT

Impulse piping
accessing direction

D45 H/L SWAP

HIGH/LOW, –5 to 110%*

3

CPU error

D52 BURN OUT

Selected from mmH

2

O, mmAq,

mmWG, mmHg, Torr, Pa, hPa, kPa,
MPa, mbar, bar, gf/cm

2

, kgf/cm

2

,

inH

2

O, inHg, ftH

2

O, psi, or atm

Static pressure setting
units

D31 STAT. P. UNIT

Hardware error

D53

Same as A60

HOLD/HIGH/LOW, –5 to 110%*

3

ERROR OUT

Self-diagnostic
messages

D60 SELF CHECK

Auxiliary setting data 2

E

OFF/ON

Menu name

AUX SET 2

Bidirectional mode

E30 BI DIRE

MODE

Same as A60

Self-diagnostic
messages

E60 SELF CHECK

No.

Description

Remarks

Item

Menu name

Automatic setup

H

AUTO SET

Adjustment data

J

–5 to 110.0%*

3

Menu name

ADJUST

Automatic zero
adjustment

J10 ZERO ADJ

Manual zero
adjustment

J11 ZERO DEV.

ENABLE/INHIBIT

External zero-
adjustment screw
permission

J20 EXT. ZERO

ADJ

Same as A60

Self-diagnostic
messages

J60 SELF CHECK

Display the error

History of the errors

RECORD

Last error

P10
P11

ERROR REC 1

Display the error

One time before

ERROR REC 2

P12

Display the error

Two time before

ERROR REC 3

Menu name

Tests

K

TEST

–5 to 110.0%*

3

Displays ‘ACTIVE’

while executing

Test output % setting

K10 OUTPUT in %

Same as A60

Self-diagnostic
messages

K60 SELF CHECK

Menu name

Memo

M

P

MEMO

8 uppercase alphanumerics

Memo

M10 MEMO 1

8 uppercase alphanumerics

Memo

M20 MEMO 2

8 uppercase alphanumerics

P13

Display the error

Three time before

ERROR REC 4

P60

Same as A60

Self-diagnostic
messages

SELF CHECK

Memo

M30 MEMO 3

8 uppercase alphanumerics

Memo

M40 MEMO 4

8 uppercase alphanumerics

Memo

M50 MEMO 5

Same as A60

Self-diagnostic
messages

M60 SELF CHECK

–32000 to 32000

Automatic measure-
ment range lower
range value setup

H10 AUTO LRV

–32000 to 32000

Automatic
measurement range
higher range value
setup

H11 AUTO HRV

–10.00 to 10.00%

0.00%

0.00%

Manual span adjustment

J15 SPAN ADJ

–10.00 to 10.00%

4mA adjustment

J30 OUTPUT 4mA

0.00%

–10.00 to 10.00%

20mA adjustment

J31 OUTPUT 20mA

Same as A60

Self-diagnostic
messages

H60 SELF CHECK

Applica-

bility

P L

F

As specified when ordered.
If not specified, MPa.

If not specified, NORMAL.
NORMAL

HIGH

HIGH

OFF

OFF/ON

Auto-recover from
sensor error

E50 AUTO

RECOVER

ON

OFF/ON*

5

DFS mode

E10 DFS MODE

ON

AMP. TEMP/CAP. TEMP*

5

Reference temperature
sensor

E14 TEMP

SELECT

CAP. TEMP

Ϯ10.00*

5

Zero shift
conpensation setup

E15 TEMP ZERO

0.00

Displays the same data as
C21.

Displays the same data as
C22.

Rewrita-

bility

Default Value

*1: In case of Model EJA120A, static pressure cannot be measured. The display is always 0 MPa, but this is not a measured value.
*2: When Optional code /F1 is specified, substitute the value with 0.1.
*3: When Optional code /F1 is specified, substitute the value –5 with –2.5.
*4: Not applicable for Model EJA115.
*5: Applicable only for Model EJA118W, EJA118N, EJA118Y, EJA438W, and EJA438N.
*6: See MWP(max. working pressure) on the nameplate. B40 shows an approximate value of maximum pressure for the capsule.