Specifications, 42 specifications, Specifications, 42 – Watlow Series 945, 1/4 DIN Microprocessor-BasedAuto-tuning Control User Manual
Page 42
Appendix
42
WATLOW Series 945 User's Manual
Specifications
Secondary Output (Heat, Cool or None)
• Solid state relay, Form A, 0.5A @ 24VAC min., 264VAC
maximum, opto-isolated, zero cross switching. Off state
impedance is 20K
Ω
minimum for 945A-XBXX-X000
units, and 31M
Ω
for 945A-XKXX-X000 units.
• Electromechanical relay, Form A, 6A @ 120/240VAC, 6A
@ 28VDC, 1/8 hp. @ 120VAC, 125VA @ 120VAC. Off
state impedance is 20K
Ω
min. Typical relay life is
100,000 cycles.
• Switched DC (Open collector), 500
Ω
min. load resis-
tance, 1K
Ω
load, 9mA min., 22mA max., non-isolated.
Alarms
• Electromechanical relay, Form A (N.O.) or B (N.C.), 6A
@ 120/240VAC, 6A
@ 28VDC, 1/8 hp. @ 120VAC,
125VA @ 120VAC. Off state impedance is 20K
Ω
min.
Typical relay life is 100,000 cycles.
• Latching or non-latching.
• Process or deviation.
• Separate high and low values.
• Alarm silencing (inhibit) on power up for Alarm 1.
Retransmit Output
• 4-20mA into a 600
Ω
maximum load, non-isolated.
• 0-5VDC into a 10K
Ω
minimum load, non-isolated.
• Retransmit of process or set point. User selectable range.
Accuracy
• Calibration Accuracy & Sensor Conformity:
±
0.1% of
span,
±
1LSD, 77
°
F
±
5
°
F(25
°
C
±
3
°
C) ambient & rated
line voltage
±
10%.
• Accuracy Span: 1000
°
F or 540
°
C minimum.
• Temperature Stability: 0.1
°
F/
°
F (0.1
°
C/
°
C) change in
ambient.
• Voltage Stability:
±
0.01% of span / % of rated line
voltage.
Communications
• Serial data communications.
• RS-422A or RS-423A (RS-232C compatible) or EIA-485.
• ANSI X3.28 protocol, or XON/XOFF protocol.
• Isolated.
• Data logging.
• #6 compression type screw terminals.
Agency Approvals
• UL recognized, File #E43684, UL873.
• CSA recognized, File # LR30586.
Terminals
• #6 compression type screw terminals.
Power
• 120/240VAC +10%, -15%, 50/60Hz,
±
5%.
• 16VA maximum.
• Data retention upon power failure via nonvolatile
memory.
Operating Environment
• 32 to 149
°
F/0 to 65
°
C.
• 0 to 90% RH, non-condensing.
Dimensions
• Height:
3.8 in
97 mm
• Width:
3.8 in
97 mm
• Overall depth:
7.0 in
178 mm
• Behind panel depth:
6.0 in
153 mm
• Weight:
2.5 lb max.
0.4 kg
Control Mode
• Single or dual set point, non-ramping.
• Single input, dual outputs, dual alarms.
• Optional retransmit of set point or process variable.
• Control outputs: User selectable as: Heat, Heat/Heat,
Heat/Cool, Cool, Cool/Cool, Cool/Heat.
• Outputs independent, or related via deadband for
Heat/Cool.
• ON/OFF: Determined by the HYSX parameter for
Outputs 1 and 2.
• Proportional band: 0 to 999
°
F/0 to 555
°
C/0 to 999 U
or 0 to 999.9% of span.
Reset: 0.00 to 9.99 repeats per minute.
Integral: 0 and 00.1 to 99.9 minutes per repeat.
Rate/Derivative: 0.00 to 9.99 minutes.
Cycle time: 1 to 60 seconds.
• Dead band:
±
99
°
F,
±
99 units or
±
55
°
C (
±
9.9
°
F,
±
9.9
units or
±
5.5
°
C for rtd.1 and process units)
Operator Interface
• Membrane front panel.
• Dual, four digit 0.56" (14 mm) LED displays.
• MODE, AUTO/MANUAL, UP, and DOWN keys.
Input
• Automatic cold junction compensation for thermocouple.
• RTD input 2 or 3 wire, platinum, 100 ohm @ 0
°
C
software selectable, JIS curve #3916 (0.003916
Ω
/
Ω
/
°
C)
or DIN curve #3850(0.003850
Ω
/
Ω
/
°
C).
• Sensor break protection de-energizes control outputs to
protect system or selectable bumpless transfer to
manual operation.
• Grounded or ungrounded sensors.
•
°
F,
°
C, or process variable units are user selectable.
• Operating ranges user selectable.
J t/c:
32 to
1382
°
F or
0 to
750
°
C
K t/c:
-328 to
2282
°
F or
-200 to 1250
°
C
T t/c:
-328 to
662
°
F or -200 to
350
°
C
N t/c:
32 to
2282
°
F or
0 to 1250
°
C
C t/c:
797 to
4200
°
F or
425 to 2315
°
C
PT 2 (Platinel 2) 32 to
2543
°
F or
0 to 1395
°
C
R t/c:
32 to
2642
°
F or
0 to 1450
°
C
S t/c:
32 to
2642
°
F or
0 to 1450
°
C
B t/c:
1598 to
3092
°
F or
870 to 1700
°
C
1
°
RTD:
-328 to
1112
°
F or
-200 to 600
°
C
0.1
°
RTD:
-99.9 to
392.0
°
F or -99.9 to 200.0
°
C
0-5VDC:
-500 to 3500 units
4-20mA:
-500 to 3500 units
Primary Output (Heating or Cooling)
• Solid state relay, 0.5A @ 24VAC min., 264VAC max.
opto-isolated, zero cross switching. Off state impedance
is 20K
Ω
min. for 952A-XBXX-X000 units, and 31M
Ω
for 945A-XKXX-X000 units.
• Electromechanical relay, Form C, 6A @ 120/240VAC, 6A
@ 28VDC, 1/8 hp. @ 120VAC, 125VA @ 120VAC. Off
state impedance is 20K
Ω
minimum. Typical relay life of
100,000 cycles.
• Switched DC (Open collector), 500
Ω
min. load resis
tance, 1K
Ω
load,9mA min., 22mA max., non-isolated.
• 4-20mA reverse or direct acting into a 600
Ω
maximum
load impedance,non-isolated.
• 0-5 VDC reverse or direct into a 1K
Ω
minimum load
impedance, non-isolated.
(1359)