Setupmenu, 14 setup parameters, Setup menu – Watlow Series 945, 1/4 DIN Microprocessor-BasedAuto-tuning Control User Manual

Page 14: Setup parameters

background image

Setup, Chapter 4

14

WATLOW Series 945 User's Manual

Setup Menu

Figure 31 -
The Setup Menu

NOTE:
The rL and rH
parameters are used
to scale the display
for process inputs,
and/or will scale the
retransmit range for
process output. rL
and rH also limit the
range of the set
point.

= Parameter may or may not appear
depending on control configuration.

= Only appear if your unit has com-

munications. See the Series 945
data communications manual for more
information on these parameters.

M

LOC

In

dEC

C _ F

rL

rH

Ot 1

HYS1

Ot 2

HYS2

AL 1

LAt1

HYS3

AL 2

LAt2

HYS4

SIL

rtd

bAUd

Prot

Addr

Log

Int

tAg

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

75

( )

dAtA

rSP

( )

LSL

USL

LinE

Mon

dAY

HOUr

( )

( )

( )

( )

( )

( )

( )

YEAr

Min

( )

[Set Point]

User lock out

Input type

Remote set point

Decimal place

Celcius_Fahrenheit

Range low

Range high

Output 1

Hysteresis 1

Output 2

Hysteresis 2

Alarm 1

Latching for alarm 1

Hysteresis 3

Alarm 2

Latching for alarm 2

Hysteresis 4

Silence alarm

RTD calibration curve

Baud rate

Data bits and parity

Protocol type

Address

Logging printout

Lower spec limit

Upper spec limit

Lines per page

Current year

Current month

Current day

Real time hour

Real time minutes

Time interval

Variables to transmit

Ot4

( )

Output 4

tbS

( )

Time base

Setup Parameters

When you are at the top of the menu, the Series 945 displays the user level of
operation in the upper display, and the LOC parameter in the lower display.

Press the MODE key and the value of the next parameter appears in the upper
display, the prompt appears in the lower display. For units with process input, see
the L-r parameter on Page 20 for how LOC is affected.

Lock: Selects the level of operator lockout. Range: 0 - 3

Default: 0

LOC 0: All operating parameters may be viewed or changed. Manual operation is
permitted. Bumpless transfer to manual operation can occur on sensor break.

LOC 1: The set point, actual, and L-r (if rSP is enabled) are the only visible parameters,

set point is adjustable in this level. Manual operation is permitted. Bumpless
transfer to manual operation can occur on sensor break.

LOC 2: The set point, actual, and L-r (if rSP is enabled) are the only visible parameters,

set point is adjustable in this level. Manual operation is not permitted.
Bumpless transfer is defeated, outputs are disabled on sensor break.

LOC 3: The set point and actual are the only visible parameters, set point is not

adjustable in this level of lockout. Manual operation is not permitted. Bumpless
transfer is defeated, outputs are disabled on sensor break.