Operations menu overview – Watlow Series 935A User Manual
Page 13
Watlow Series 935A User’s Manual
1 1
Table 4 - Operations Menu Overview
To enter the Operations Menu, press the
.
and
,
keys simultaneously for three seconds.
Auto-tune - Start the auto-tune action to automatically select a set of viable PID values;
[tunE]
will flash during auto-tuning.
[``no]
[`YES]
NO
YES
Alarm Low - Select a low alarm point, adjustable between Off, Range Low and Alarm High.
[`AhI]
Alarm High
Alarm High - Select a high alarm point, adjustable between Alarm Low and Range High, or OFF.
[`ALO]
Alarm Low
Countdown Timer - Select a countdown time duration.
[0)º0]
[9959]
00:00 to 99:59 Hrs:Min or Min:Sec
Idle Set Point Type - Choose to track set point, or select a separate idle set point adjustable between Range Low and Range High. When
[`Ot1]
=
[thM]
or
[tMS]
, view the idle set point from the set point display with a three second
ß
press.
[trAc]
[``rL]
[``rh]
Track
Range Range
Set
Low
High
Point
Local / Remote Set Point - Choose to use the remote set point input.
[```L]
[```r]
Local
Remote
PID Menu - Go to the PID Menu.
[``no]
`YES]
NO
YES
Configuration Menu - Go to the Configuration Menu.
[``no]
`YES]
NO
YES
[`Aut]
[`ALO]
[`AhI]
[tMr]
[IDLE]
[`L-r]
[`Pid]
[CnFg]