5

Output Rating Curves

0

5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80

25

30

35

40

45

50

55

60

65

70

75

80

90

85

Current (Amps) into a Resistive Load

M

a

x

im

u

m

I

n

te

rn

a

l

E

n

c

lo

s

u

re

A

m

b

ie

n

t

T

e

m

p

e

ra

tu

re

(

°

C

)

DIN-A-MITE Style C Ratings at 100% On

Natural Convection

3

-p

h

a

s

e

, 3

-le

g

3

-p

h

a

s

e

, 2

-le

g

S

in

g

le

-p

h

as

e

0

5

10 15 20 25 30 35 40 45 50 55 60 65 70

25

30

35

40

45

50

55

60

65

70

Current (Amps) into a Resistive Load

M

a

x

im

u

m

I

n

te

rn

a

l

E

n

c

lo

s

u

re

A

m

b

ie

n

t

T

e

m

p

e

ra

tu

re

(

°

C

)

DIN-A-MITE Style C Ratings at 100% On

75 80 85 90

Fan-Cooled

75

80

3-

p

h

as

e,

3-

le

g

3-

p

h

as

e,

2-

le

g

S

in

g

le

-p

h

a

s

e

Extended Heater And SCR Life
With Variable Time Base

Models: DC _ _ - [02, 24, 60] F0 - _ _ _ _

20% Power, 3 AC line cycles on, 12 cycles off

50% Power, 3 AC line cycles on, 3 cycles off

Phase Angle

Single-Cycle Variable Time Base

With single-cycle variable time base (VTBS)
control, at 50% power, power is on one cycle, and
off one cycle. At 25%, it is on for one cycle and
off for three. Under 50%, the unit is not on for
more than one consecutive cycle. Over 50%, the
unit is not off for more than one consecutive
cycle. This model will work with a linear voltage
input, a 4 to 20mA input or a potentiometer
input.

Phase angle control (control Type P) is infinitely
variable inside the sine wave. This provides a
variable voltage and/or current output. This
option includes soft start and line voltage
compensation. This model will work with a linear
voltage input, a linear current source input or a
potentiometer input. This is single-phase only.
Alarms not available on phase angle models.

Models: DC _ _ - _ _ S _ - _ _ _ _

25% Power, 1 AC line cycle on, 3 cycles off

Models: DC1 _ - _ _ [L, P] _ - 0 _ _ _

With variable time base control, the power
controller automatically adjusts the time base
and output power with respect to process input.
Accelerated life testing verified that the variable
time base control significantly reduces
expansion and contraction of the heater element.
This extends heater and SCR life while
improving the process temperature control. You
save money on heaters, down time and
maintenance.

50% Power, 1 AC line cycle on, 1 cycle off

Ó

6

0

5

10 15 20 25 30 35 40 45 50 55 60 65 70

Current (Amps) into a Resistive Load

25

30

35

40

45

50

55

60

65

70

75

80

A

m

b

ie

n

t

A

ir

A

ro

u

n

d

H

e

a

ts

in

k

F

in

s

(

C

)

DIN-A-MITE Style C Ratings at 100% On

Through-Wall Heatsink

75 80

Recommended maximum

enclosure temperature is 80 C (176 F)

3-p

ha

se

, 2

-le

g

3

-p

h

a

s

e

,

3

-le

g

S

in

g

le

-p

h

as

e

Combination Fuses for Applications Through 600V

Å

(ac):

Semiconductor

Watlow Fuse

Bussman

Watlow Holder

Bussmann Holder

Fuse Rating

P/N

P/N

P/N

P/N

30A

0808-0325-0030

DFJ30

0808-0326-1530

CH30J1i

40A

0808-0325-0040

DFJ40

0808-0325-3560

CH60J1i

50A

0808-0325-0050

DFJ50

0808-0325-3560

CH60J1i

63A

0808-0325-0060

DFJ60

0808-0325-3560

CH60J1i

80A

0808-0325-0080

DFJ80

0808-0325-7010

J60100-1CR

100A

0808-0325-0100

DFJ100

0808-0325-7010

J60100-1CR