Proface APL3000B - Node Box PC User Manual
Page 72
Chapter 3 Installation and Wiring
3-17
Power Cord Specifications
Wiring
When connecting the power cord, use the following items when performing wiring. (Items are made by
Phoenix Contact.
*1
)
Connecting the Power Cord
(1)
Confirm that the power is not supplied to the PS-B unit.
(2)
Unplug the power connector from the top of the PS-B unit.
(3)
Push the Opening button with a small and flat screw driver to open the desired pin hole.
Power Cord Diameter
0.75 to 2.5mm
2
(18 to 12 AWG)
Conductor Type
Simple or Stranded Wire
*1
*1
If the Conductor’s end (individual) wires are not twisted correctly, the end
wires may either short against each other, or against an electrode.
Conductor Length
• Use copper conductors only.
Recommended Driver
SZS 0.6x3.5 (1205053)
Recommended Pin Terminals
AI 0.75-10GY (3201288)
AI 1-10RD (3200182)
AI 1.5-10BK (3200195)
AI 2.5-12BU (3200962)
Recommended Pin Terminal Crimp Tool
CRIMPFOX ZA3 (1201882)
•
Accompanying AC type power supply connector (plug) is CA7-ACCNL-01 from
Pro-face or FKC2.5/3-STF-5.08 is manufactured by Phoenix Contact
*1
.
*1
For details, please contact your local Phoenix Contact distributor.
10mm[0.39in.]