Wiring Precautions
This section describes the procedures and precautions for wiring power cords.
3.3.1
Connecting the Power Cord
AC Connections
Be sure to confirm that power is not being supplied to the PS-B unit before wiring . Failure
to do so can result in an electric shock.
Supplying a power voltage other than that specified will damage the power source and the
PS-B unit.
Since there is no power switch on the DC type PS-B unit, be sure to attach a breaker-type
switch to its power cord.
When the FG terminal is connected, be sure the wire is grounded.
• When the FG terminal is connected, be sure the wire is grounded. Not grounding
the PS-B unit will result in excess noise and vibration.
• The SG and FG terminals are connected internally in the PS-B unit.
When connecting the SG wire to another device, be sure that the design of the
system/connection does not produce a shorting loop.
The PS-B units is designed to use AC100V to 240V input. Supplying a power voltage other