HYDRAULIC SYSTEM REQUIREMENTS

Refer to the performance charts, below, to properly match your hydraulic
system to H-800 Dow-Lok® winch performance. The charts consist of :
(1) Line pull (lb.) first layer vs. working pressure (PSI). STATIC (solid line)

refers to hoisting a suspended load from rest; DYNAMIC (dotted line)
refers to maintaining the motion of a moving load.

(2) Line speed, first layer (FPM) vs. Flow, gallons per minute (GPM).
Performance based on a motor displacement of 14.9 cubic inches with 30
GPM maximum flow rate. See page 15 for motor port size.

H-800 PERFORMANCE
25,000 LB. DUTY RATING

TYPICAL HYDRAULIC LAYOUT

WORKING PRESSURE, PSI

FIRST LAYER

LINE PULL, LBS

0

0

10000

5000

20000

15000

25000

DYN

AM

IC

STATI

C

2000

1000

3000

FLOW, GPM

FIRST LAYER

LINE SPEED, FPM

0

0

10

5

10

15

20

20

30

30 GPM

2750 PSI

SYSTEM

RELIEF

A PORT

MOTOR CONTROL VALVE

MOTOR

B

A

4 WAY VALVE

(MOTOR SPOOL)

3 POSITION

PRESSURE AT

RATED LOAD:

MAX. FLOW &

PUMP