background image

Refer to the performance charts below to properly match your hydraulic system to the winch performance. The
charts consist of: (1) Line Pull first layer kN (lb) vs. Working Pressure bar (PSI). (2) Line Speed, first layer MPM
(FPM) vs. flow LPM (GPM).

HYDRAULIC SYSTEM REQUIREMENTS

1.

Motor spool (open center) control valve

2.

Emergency Stop:
A. If winch is controlled by a direct-operated manual valve, that valve serves as the E-stop.
B. If a remote operated control valve is used, a solenoid-operated hydraulic dump valve, normally open to

tank, and an emergency stop switch (to open the dump valve) is required. The E-stop switch is to be
normally closed and have a red, resettable push button actuator with a yellow background. The E-stop
switch must be easily accessible to the operator.

3.

Relief valve set to 172,4 bar (2500 psi) which is the rated capacity limiter.

4.

Flow rate of 56,7 LPM (15 GPM) maximum. Do not exceed 75,7 LPM (20 GPM) or motor and winch may
be damaged.

5.

Hydraulic fluid with a viscosity between 20-43 cSt (100-200 SUS). Maximum operating temperature
85C (180F). Cleanliness level of ISO 17-14 or better.

7