beautypg.com

2 recommended installation tools, 3 power requirements, 4 environmental requirements – Asante Technologies 3624/48 User Manual

Page 15: 5 cooling and airflow, 2 installing into an equipment rack

background image

Do not tamper with the equipment. Doing so could void the warranty

Examine the work area for potential hazards (such as wet floors or ungrounded cables)

2.1.2 Recommended Installation Tools

You need the following additional tools and equipment to install the switch into an equipment rack:

Flat head screwdriver

Phillips head screwdriver

Antistatic mat or foam

2.1.3 Power Requirements

The electrical outlet should be properly grounded, located near the switch and be easily accessible. Make sure the
power source adheres to the following guidelines:

Power: Auto Switching AC, 90-240 VAC

Frequency range: 50/60 Hz

2.1.4 Environmental Requirements

Install the switch in a clean, dry, dust-free area with adequate air circulation to maintain the following environmental
limits:

Operating Temperature: 0° to 40°C (32° to 104°F)

Relative Humidity: 5% to 95% non-condensing

Avoid direct sunlight, heat sources, or areas with high levels of electromagnetic interference. Failure to observe these
limits may cause damage to the switch and void the warranty.

2.1.5 Cooling and Airflow

The IntraCore IC3624/48 switch uses internal fans for air-cooling. Do not restrict airflow by covering or obstructing air
vents on the sides of the switch.

2.2 Installing into an Equipment Rack

Important: Before continuing, disconnect all cables from the switch.

To mount the switch into an equipment rack:

15

Asante IntraCore IC3624/48

User’s Manual