beautypg.com

Appendix c loop status messages, Loop status messages – ADTRAN 3000 User Manual

Page 127

background image

61203153L2-20

Express 3000 User Manual

C-1

Appendix C

Loop Status Messages

This appendix lists the status line messages and their definitions.

AutoSpid X

The SPID is being attempted by the AutoSpid determination.
X starts at 0 and counts up for each SPID tried.

Call Connect B1

Bearer channel 1 is connected and is active.

Call Connect B2

Bearer channel 2 is connected and is active.

Call Connect B1/B2

Bearer channels 1 and 2 are active.

Disconnecting

The current phone call is being disconnected (hung up).

Getting TEI #1

The Express 3000 is receiving its first TEI from the network.

Getting TEI #2

The Express 3000 is receiving its second TEI from the network.

Link Down

The network interface is not in sync.

Network Loopback

The Express 3000 has been commanded to perform an ISDN
loopback toward the network.

Ready

The unit is ready to make or accept a call.