S-registers list – ADTRAN 3000 User Manual
Page 107

Appendix A. AT Commands and S-Registers
61203153L2-20
Express 3000 User Manual
A-9
S-Registers List
Command
Function
Features
S00
Auto Answer
Determines how the Express 3000 answers an incoming
call.
0 = Disable (Express 3000 does not answer call).
1 = Enable (Express 3000 answers all calls).
2 = Dump all calls.
S02
Escape Character
Determines which key or character (in ASCII code)
defines the escape command. The standard escape
character is a plus (+) sign (ASCII value of 43 decimal).
To change the character set, set S2 to the desired ASCII
value.
Range = 0 to 127
S03
End of Line
Character
Determines which key or character (in
ASCII code) ends a command line. The standard end-of-
line character is the carriage return (ASCII value of 13
decimal).
Range = 0 to 127
S04
Line Feed
Character
Determines which key or character (in
ASCII code) advances the cursor to the next line after
ending a command line or after an Express 3000 message.
The standard character is the line feed (ASCII value of 10
decimal).
Range = 0 to 127
S05
Back Space
Character
Determines which key moves the cursor back one space to
erase a character. The standard character is the backspace
(ASCII value of 8 decimal).
Range = 0 to 127
S06
Enable
AO/DI
S6 = 0 for disable
S6 = 1 for enable
S07
Connect
Time
Determines how long the Express 3000 waits for an
outgoing call to be answered.
15 = 15 seconds
30 = 30 seconds
60 = 1 minute
120 = 2 minutes
240 = 4 minutes