Checking errors, Checking the version and serial number – Lincoln Electric 718114 Spirit II 150 User Manual
Page 49
![background image](/manuals/356731/49/background.png)
Spirit II User’s Manual
Section 4: Operation with Manual Gas Console
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
4-7
Checking Errors
The last ten (10) system errors are available through the MGC as described below.
On the main menu, move the pointer to
Errors.
Press SELECT.
Press SELECT to cycle through the last ten
(10) error codes.
See Section 6 in this manual for details on the
error codes.
Simultaneously pressing DOWN and SELECT
will erase all ten error codes.
Move the pointer to
Return and press
SELECT to return to the main menu.
Checking the Version and Serial Number
The hardware version, software version and serial number for the Power Supply and
Gas Console can be displayed as described below.
On the main menu, move the pointer to
Version. Press SELECT.
Move the pointer to either
Power Supply or
Gas Console. Press SELECT.
Review the necessary information.
Press SELECT to return to the previous
screen.
Move the pointer to
Return and press
SELECT to return to the main menu.