Section 4: operation, Operating the manual gas console (mgc) – Lincoln Electric 718114 Spirit II 150 User Manual
Page 43
Spirit II User’s Manual
Section 4: Operation with Manual Gas Console
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
4-1
Section 4: Operation
Operating the Manual Gas Console (MGC)
The Manual Gas Console (MGC) is the interface to the entire Spirit system when the
MGC is used instead of the Automatic Gas Console (AGC).
OFF Button
Push to disable the Spirit system.
Release (turn to the right) to enable
the system, which can then be
energized by choosing ON and then
SELECT.
Up/Down/Select Buttons
Press the up or down button to move
the pointer ( ) accordingly on the
display. These buttons are
represented as UP and DOWN
throughout this manual.
Press the select button to access
menu items or settings identified by
the pointer. This button is shown as
SELECT throughout this manual.
Display
The display turns on automatically
when AC power is applied to the
Spirit system. It displays the menu
tree, which is navigated using the
Up/Down/Select buttons and is used
to control the entire Spirit system.
Pressure Regulator Knobs
Turn to the left or right to adjust the
amount of output gas pressure for
PreFlow, PostFlow, Plasma and
Shield gases.