Filling the cooling system – Lincoln Electric 718114 Spirit II 150 User Manual
Page 42
Section 3: Installation
Spirit II User’s Manual
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
3-20
Filling the Cooling System
WARNING: Do not touch the fans inside the power supply.
Important: Never turn on the system when the coolant reservoir is empty.
Important: When handling coolant, wear nitrile gloves and safety glasses.
Important: Only use Kaliburn approved coolant. Commercially available
antifreeze contains corrosion inhibitors that will damage the cooling
system. See Section 2 for more information.
1. Remove primary power from the Spirit system.
2. Ensure the torch base and torch head (with consumables) are properly installed.
3. Ensure the coolant supply (in and out) hoses are properly installed.
4. Remove the coolant reservoir cap/level gauge and then remove the top, left and
right covers from the power supply.
5. Ensure the coolant filter housing is tightened securely.
6. Ensure the drain petcock on the bottom of the reservoir is tightened securely.
7. Fill the reservoir with approximately 2 ½ gallons of approved coolant.
8. Apply primary power to the Spirit system and enable it by releasing (turn right) the
OFF Button on the MGC.
9. On the MGC main menu, move the pointer to On. Press SELECT to start the
coolant pump circulating coolant through the system. Note: The coolant pump will
turn off automatically if the coolant level drops below the minimum level inside the
reservoir. If this happens, add more coolant.
10. With the coolant pump running, locate the small red push-button on top of the
coolant filter housing (beneath the reservoir). Press and hold the red button until no
air or bubbles are seen inside the filter housing. Dry any coolant that leaks out.
11. Check for coolant leaks at all hose connections, the ISC, and at the torch.
12. Push the OFF Button on the MGC to stop the coolant pump.
13. Remove primary power from the Spirit system.
14. Fill the reservoir with coolant until the coolant gauge indicates full.
15. Replace the power supply covers and replace the coolant reservoir cap/level gauge.
16. End of procedure.