Imperial, Metric, Marking* – for all material thicknesses – Lincoln Electric 718113 Spirit II 150 User Manual
Page 94
Section 5: Torch Consumables and Cutting Charts
Spirit II User’s Manual
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
5-24
Stainless Steel - 150 Amps - H17 Plasma / Nitrogen Shield
Copper Electrode
(H17 = 17.5% Hydrogen / 32.5% Argon / 50% Nitrogen)
This gas combination gives the best cut quality and minimum dross levels
Shield Cap
Nozzle
Electrode
277298
277297
277135
Outer Cap
Retaining Cap
Swirl Ring
Torch Head
284150
277266
277139
279100
Imperial*
Material
Thickness
Preflow
Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(in)
(psi)
(psi)
(psi)
(psi)
(volts)
(ipm)
(in)
(in)
(msec)
(in)
1/4
25
77
75
81
165
95
.250
.250
400
.135
3/8
75
.150
.275
500
1/2
60
.165
.300
600
.140
5/8
50
.185
.325
800
3/4
40
.250
.350
1200
.145
Metric*
Material
Thickness
Preflow
Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(mm)
(psi)
(psi)
(psi)
(psi)
(volts)
(mm/m)
(mm)
(mm)
(msec)
(mm)
10
25
77
75
81
155
1845
3.8
7.0
600
3.4
12
1610
4.1
7.4
3.6
16
1260
4.7
8.3
800
20
167
940
6.9
9.0
1200
3.7
Marking* – For All Material Thicknesses
Type of Gas
Preflow Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Marking
Height
Initial
Height
Pierce
Time
(Plasma) (Shield)
(psi)
(psi)
(psi)
(psi)
(volts)
(ipm) (mm/min) (in) (mm) (in) (mm) (msec)
Nitrogen Nitrogen
N/A
25
25
N/A
135
250
6350
.100 2.5 .100 2.5
0
Argon** Nitrogen**
N/A
50
25
N/A
81
100
2540
.140 3.6 .100 2.5
0
* Use an arc transfer height (ignition height) of .200” (5.1 mm) for cutting and .100” (2.5 mm) for marking.
** Only available on systems with the Automatic Gas Console.