Spirit II User’s Manual

Section 4: Operation with Automatic Gas Console

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

4-3

Setting up to Cut or Mark

Press the Material navigation button to setup a cut or mark. Material type, material

thickness, and process (cut or mark) are the only parameters that must be selected. All

other parameters are adjusted automatically; however, these parameters can be

customized. See Customizing Cutting or Marking Settings for more information.

Select Material Type

Press the Material Selection button

and select the desired material from

the list. Choose cancel to return to

the previously selected material.

Select Material Thickness

Press the Thickness Selection button

to choose from a list of predefined

gauges and thicknesses or press the

data entry button ( ) to manually

enter a thickness.

Select Cut or Mark (Process)

Press Cut or Mark to select the

desired process and the default gases

will be displayed.

The selected process will have a light

blue background.

Note: The X/Y controller can

automatically override the selected

process unless the cut/mark/cut

configuration is set to Local.