B-7

Command

# Hex String

Additional Information

Cutting Chart

Version

34 AA nn FA 22 00 -- 0D

If requested in command #30, the system will

transmit the cutting chart version x 10.

Number of Pierces

35 AA nn FA 23 00 -- 0D

If requested in command #30, the system will

transmit the number of pierces. Range: 0 to 9999

Number of Pierce

Errors

36 AA nn FA 24 00 -- 0D

If requested in command #30, the system will

transmit the number of pierce errors. Range: 0 to

9999

Reset Pierce

Counter

37 AA nn FA 25 00 01 0D

Resets number of pierces and errors to 0

Power On

38 AA nn FA 26 00 01 0D

Energizes power supply, torch coolant pump and

cooling fans. If torch coolant flow switch not

satisfied within 8 seconds, unit will power down.

Power Off

39 AA nn FA 27 00 01 0D

Deenergizes power supply, torch coolant pump

and cooling fans

Request System

Status

40 AA nn FA 28 00 01 0D

System status can only be requested after a

Power On command (#38) is transmitted. The

status is returned in the following form: (All bits:

0=fault; 1=ok)

LSB Bit 0 = ISC Door

LSB Bit 1 = AC Power

LSB Bit 2 = Coolant Flow

LSB Bit 3 = Coolant Level

LSB Bit 4 = Coolant Temp

LSB Bit 5 = AGC status

LSB Bit 6 = Inlet Gas Pressures

LSB Bit 7 = Not used

MSB Bit 0 = Not used

MSB Bit 1 = Hydrogen Cutting Enabled

Purge Gases

41 AA nn FA 29 00 01 0D

Purges gas lines

Set Cutting Arc

Voltage

42 AA nn FA 2A -- -- 0D

Sets cutting arc voltage in Volts x 100

Valid Range: 5000 to 20000

Set Cutting Height

43 AA nn FA 2B -- -- 0D

Sets cutting height in mils (inches / 1000)

Valid Range: 0 to 999

Set Cutting Pierce

Height

44 AA nn FA 2C -- -- 0D

Sets cutting pierce height in mils (inches / 1000)

Valid Range: 0 to 999

Set Cutting Travel

Speed

45 AA nn FA 2D -- -- 0D

Sets cutting travel speed (inches / min) displayed

on the voltage screen

Valid Range: 0 to 999

Save as User File

46 AA nn FA 2E 00 01 0D Saves the present cutting conditions as a user

file.