Imperial, Metric, Marking* – for all material thicknesses – Lincoln Electric 718113 Spirit II 150 User Manual
Page 93
Spirit II User’s Manual
Section 5: Torch Consumables and Cutting Charts
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
5-23
Stainless Steel - 100 Amps - Air Plasma / Nitrogen Shield
Copper Electrode
This gas combination gives medium cut quality and minimum dross levels
Shield Cap
Nozzle
Electrode
277286
277284
277282
Outer Cap
Retaining Cap
Swirl Ring
Torch Head
284150
277151
277283
279100
Imperial*
Material
Thickness
Preflow
Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(in)
(psi)
(psi)
(psi)
(psi)
(volts)
(ipm)
(in)
(in)
(msec)
(in)
1/4
25
80
35
80
141
100
.135
.225
400
.092
3/8
147
80
.170
.250
500
.095
1/2
154
55
.210
.300
600
Metric*
Material
Thickness
Preflow
Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(mm)
(psi)
(psi)
(psi)
(psi)
(volts)
(mm/m)
(mm)
(mm)
(msec)
(mm)
6
25
80
35
80
140
2595
3.2
5.6
400
2.3
10
148
1935
4.4
6.5
600
2.4
12
152
1540
5.0
7.3
Marking* – For All Material Thicknesses
Type of Gas
Preflow Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Marking
Height
Initial
Height
Pierce
Time
(Plasma) (Shield)
(psi)
(psi)
(psi)
(psi)
(volts)
(ipm) (mm/min) (in) (mm) (in) (mm) (msec)
Nitrogen Nitrogen
N/A
25
25
N/A
130
250
6350
.100 2.5 .100 2.5
0
Argon** Nitrogen**
N/A
50
25
N/A
68
100
2540
.100 2.5 .100 2.5
0
* Use an arc transfer height (ignition height) of .200” (5.1 mm) for cutting and .100” (2.5 mm) for marking.
** Only available on systems with the Automatic Gas Console.
(Revised 04/26/2013)