beautypg.com

Microprocessor (dsp) status indicators – Lincoln Electric 718113 Spirit II 150 User Manual

Page 111

background image

Spirit II User’s Manual

Section 6: Maintenance &Troubleshooting

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

6-5

Microprocessor (DSP) Status Indicators

The microprocessor DSP board controls all of the functions of the Spirit power

supply. It contains diagnostic LEDs and OPTO LEDs which aid in

troubleshooting the system. These indicators illuminate when a particular event

occurs. Illuminated LEDs indicate the following:

LED

Indication

D7 – RS232 OUT Isolated

Serial transmission

D10 – RS232 T1 OUT

Serial transmission

D11 – CAN RXD

CAN transmission

D12 – CAN TXD

CAN transmission

D24 – PWM

Chopper(s) energized

D33 – COOLANT LEVEL

Coolant reservoir level is sufficient

D36 – PLASMA START

Plasma start signal applied to Spirit

D37 – ARC HOLD

Arc hold input enabled

D38 – MARKING

Marking input enabled

D39 – CORNER

Corner current input enabled

D40 – EOFF

Off button disengaged

D41 – MOTION

Motion output signal activated

D42 – PLASMA READY

Power supply ready output signal activated

D43 – PAT

Pilot arc transistor energized

D48 – RMT ON/OFF

Remote On/Off input enabled

D50 – ISC DOOR

ISC door is closed

D77 – 3.3V uP PWR

3.3V Microprocessor power

D78 – 1.8V uP PWR

1.8V Microprocessor power

OPTO U21 – MTR/SOL

Coolant pump relay CR5 energized (Pump On)

OPTO U22 – PAR

Pilot arc relay energized

OPTO U23 – CON

DC power output (main contactor energized)

OPTO U24 – SURGE

CR3 and K1 (I/O PCB) relays energized

OPTO U26 – FAN

Fans energized

OPTO U27 – PREFLOW

Preflow gas valve 1 energized

OPTO U28 – PLASMA

Plasma gas valve 2 energized

OPTO U29 – SHIELD

Shield gas valve 3 energized

OPTO U30 – VENT

Vent gas valve 4 energized

OPTO U31 – POSTFLOW

Postflow gas valve 5 energized

OPTO U32 – MARKING

Marking gas valves 6 and 7 energized

OPTO U34 – IMPULSE START Impulse start circuit energized

OPTO U37 – RHF

HF transformer energized