Troubleshooting, Caution – Lincoln Electric IM10023 MAXsa 10 CONTROLLER User Manual

Page 38

background image

E-3

TROUBLESHOOTING

E-3

MAXsa™ 10 CONTROLLER

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Observe all Safety Guidelines detailed throughout this manual

PROBLEMS

(SyMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Err 31 Primary overcurrent

Err 32 Capacitor bank "A" under

voltage.

Err 33 Capacitor bank "B" under

voltage.

Err 34 Capacitor bank "A" overvolt-

age.

1. The power source has exceeded

input current limits. Adjust the
welding procedure to reduce the
current draw. The welding proce-
dure may exceed the capacity of
the power source.

2. See the power source Instruction

Manual.

1. The power source input power

may be wired incorrectly. Verify
the power source reconnect
panel wiring matches the input
power.

2. See the power source Instruction

Manual.

1. The power source input power

may be wired incorrectly. Verify
the power source reconnect panel
wiring matches the input power.

2. See the power source Instruction

Manual.

1. The power source input power

may be wired incorrectly. Verify
the power source reconnect
panel wiring matches the input
power.

2. See the power source Instruction

Manual.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized Field
Service Facility.

ARCLINK SySTEM ERROR CODES