OPERATION

B-15

Press the START BUTTON to begin welding.

The ARC ESTABLISHED INDICATOR will ‘flash’
as the wire feeds towards the work piece to show
that OCV is present and switch to ON when the arc
is lit.

If “Start” parameters have been set they will be in
effect for the specified time and then the Weld
Mode parameters will take effect.

The two upper displays will indicate the “actual”
parameters as the weld progresses.

If the TRAVEL function is selected it will begin
moving as prescribed in the P.12 Parameter set-
ting.

Press the STOP BUTTON to end the weld.

If “End” parameters have been set, they will take
effect for the specified time.

If the TRAVEL function is selected it will stop mov-
ing as prescribed in the P.12 Parameter setting.

The ARC ESTABLISHED INDICATOR will go OFF
when the power source output is disabled (after
Burnback).

The displays will return to the idle state in prepara-
tion for the next weld.

MAXsa™ 10 CONTROLLER

200

Steel 1/8”

CC DC

30

.

5

58

+

START

BUTTON

STOP

BUTTON

ARC ESTABLISHED

INDICATOR

FIGURE B.7 - MAKING A WELD

MAKING A WELD

Once the necessary parameters have been set and the desired Weld Mode selected: