background image

B-10

OPERATION

B-10

Parameter

Definition

Exit Setup Menu

P.0

This option is used to exit the setup menu. When P.0 is displayed, press the Left Button to exit
the setup menu

P.1

Wire Feed Speed Units

This option selects which units to use for displaying wire feed speed. English = inches/minute
wire feed speed units (default). Metric = meters/minute wire feed speed units.

P.2

Arc Display Mode

This option selects what value will be shown on the upper left display while welding. Amps =
The left display shows Amperage while welding (default). WFS = The left display shows Wire
Feed Speed while welding.

P.3

Display Options

This setup parameter was previously named "Display Energy"

If the previous software revision had this parameter set to display energy, that selection will
remain.

This option selects the information displayed on the alphanumeric displays while welding. Not all
P.3 selections will be available on all machines. In order for each selection to be included in the
list, the power source must support that feature. A software update of the power source may be
needed to include the features.

Standard Display = The lower displays will continue to show preset information during and after
a weld (default). Show Energy = Energy is displayed, along with time in HH:MM:SS format.
Show Weld Score = The accumulative weld score result is shown.

P.12

Travel Carriage Start/Stop - Travel Starts

This option allows the adjustment of the start and end travel options for a travel carriage. Press
the Right Button to enter the option and rotate the Control Knob to select either starting or end-
ing options. Press the Right Button to enter the selected option. Rotate the Control Knob to
select the desired function. After selecting the function, press the Left Button to save the func-
tion and back out to select another option. Rotate the Control Knob to make another selection,
or press the Left Button to exit this option.

P.12

Travel Carriage Start/Stop - Travel Ends

This option allows the adjustment of the start and end travel options for a travel carriage. Press
the Right Button to enter the option and rotate the Control Knob to select either starting or end-
ing options. Press the Right Button to enter the selected option. Rotate the Control Knob to
select the desired function. After selecting the function, press the Left Button to save the func-
tion and back out to select another option. Rotate the Control Knob to make another selection,
or press the Left Button to exit this option.

P.13

Arc Force Adjustment Options

This option allows the adjustment of Arc Force values for Start, Weld and Crater. Press the
Right Button to enter the option and rotate the Control Knob to select the desired weld state to
adjust. Press the Right Button again to adjust the value on the upper Left Knob. Press the Left
Button to save the value and back out to select another weld state. Rotate the Control Knob to
make another selection, or press the Left Button to exit this option. This option will not appear if
the presently selected weld mode does not support Arc Force.

P.14

Reset Consumable Weight

Use this option to reset the initial weight of the consumable package. Press the Right Button to
reset the consumable weight. This option will only appear with systems using Production
Monitoring.