LOOPBACK AND CONTROL CODES

PatternDescription

Requires Armin

g?

1in3

Loop down all units and disarm.

No

2in5

Arming Pattern, H4TU-R will loop up if Smartjack LB is enabled.

No

3in5

Disarm and loop down all units. Restores LB TMO after D5D6.

No

1in6

Network Arming Pattern. If Smartjack LB is enabled, HTU-R will loop toward network.

No

2in6

H4R LB to Network.

No

3in6

H4R LB to Network.

No

4in6

H4R LB to Customer.

No

5in6

H4R LB to Customer.

No

3in7

H4TU-R LB to Network.

No

4in7

H4TU-C LB to Network.

No

5in7

H4TU-R LB to Customer.

No

6in7

H4TU-C LB to Customer.

No

3F1E

H4TU-C LB to Customer.

No

3F02

H4TU-R LB to Customer.

No

3F04

H4R LB to Customer.

No

3F06

H4R LB to Customer.

No

6767

Disable span powering while present.

Yes

9393

Loop down H4TU-C, Repeaters - all loopbacks. Loop down H4TU-R - Cust LB always.

Will only loop down H4TU-R Network LB if NIU is disabled. Does not disarm units if they

are armed.

No

C741

H4R #1 loop up pattern. 10 bit error injection.

Yes

C742

H4TU-R loop up pattern. 20 bit error injection.

Yes

C754

H4R #2 loop up pattern. 200 bit error injection.

Yes

D3D3

H4TU-C loop up pattern. 231 bit error injection.

Yes

D5D5

Query Loopback Pattern (error injection)

H4TU-C: 231 Errors, H4R #1: 10 Errors, H4R #2: 200 Errors, H4TU-R: 20 Errors

No

D5D6

Loopback Timeout Override: Disables LB timeout. Restores original LB timeout when unit

is disarmed.

Yes

FF48

FDL Arming Pattern (ESF only). Arms all units, H4TU-R will LB to Network if NIU Enabled

(if pattern sources at network).

No

FF24

FDL Disarm Pattern (ESF only). Loop down and disarm all units

No

FF1E

H4TU-C LB to Network. Will not loop up H4TU-C if H4TU-C already in LB to Customer.

No

FF02

H4TU-R LB to Network. Will not loop up H4TU-R if any unit already in LB to Customer.

No

FF04

H4R LB to Network.

No

FF06

H4R LB to Network.

No

WARRANTY

ADTRAN will replace or repair this product within the warranty period if it does not meet its published
specifications or fails while in service. Warranty information can be found at
www.adtran.com/warranty. U.S. and Canada customer Faxback: 877-457-5007, Document 414.

ADTRAN HDSL4 equipment is designed with troubleshooting-at-a-glance features. The following information provides
suggestions for troubleshooting as a result of LED indications which are indicative of loop trouble.

NOTE: Pressing “ESC” while on any screen will go back to the previous screen.

INDICATIONS AND POSSIBLE CAUSES

DSL LED Red

Connect a terminal or PC to the RS-232 (DB-9) craft interface on the front panel. The terminal must be VT100 or compatible
and set for 1.2 to 19.2 kbps, 8 data bits, no parity, 1 stop bit, no flow control. Select “3” from the ADTRAN HDSL4 Main Menu
screen and “1” from the Span Status Screen. Verify the following conditions on the HDSL4 and T1 Detailed Status Screen:

Margin

3 dB

Attenuation

35 dB (1st segment)

Attenuation

31 dB (2nd segment)

No ES, SES, or UAS (Performance History Screen, Main
Menu Selection 5)

If the above conditions do exist, the circuit should provide
quality service; however, if any of the above conditions do not
exist, a cable problem or excessive loss situation is probable,
and more detailed cable testing should be done to verify all
HDSL4 loop specifications are met. These conditions may also
reflect intermittent cable faults or excessive noise impairments.
If intermittent faults or noise impairments are suspected, review
the Performance History Screen.

HDSL4 DEPLOYMENT GUIDELINES

The guidelines provided below apply to the segments of an
HDSL4 circuit, as follows:

1st segment = between the H4TU-C and H4R

2nd segment = between two H4Rs or single H4R and H4TU-R

3rd segment = between the second H4R and the H4TU-R

These deployment guidelines provide the basics for HDSL4 circuit provisioning. If these parameters are met, then the circuit
will provide quality service. If not, a cable problem or excessive loss situation is probable. In this case, a more detailed cable
analysis is required to ensure that all HDSL4 loop specifications are met. These conditions may also be the result of
intermittent cable faults or intermittent noise impairments. If intermittent problems are suspected, utilize the Performance
History screen to assist in troubleshooting.

1.

All loops are nonloaded only

2.

Any single bridged tap is limited to 2 kft.

3.

Total bridged tap length is limited to 2.5 kft.

4.

Bridge tap within 1000 feet of units may affect performance of the
circuit

5.

Margin

6 dB (Detailed Status Screen)

6.

No ES, SES, or UAS (Performance History Screen)

7.

Foreign Voltage DC (t-r, t-g, r-g) < 3 VDC

8.

Insulation Resistance (t-r, r-g, t-g) > 3.5 M

9.

Impulse Noise

–40 dBmF (measured with an F filter)

10. Wideband Noise

–54 dBmF

11. Longitudinal Noise (Power Influence) < 80 dBrnC

OK

80–90 dBrnc Marginal
> 90 dBrnc

Unacceptable

NOTE: The insertion loss reading shown on the Detailed Status

Screen is an approximation that is valid for some loops.
Exercise caution when using this value.

Range Limits: 26 Gauge / 70ºF / PIC

Recommended Maximum

(DSL Assistant Green Zone)

1st segment

10.8 kft.

2nd/3rd segment

10.55 kft.

Range Limits: 24 Gauge / 70ºF / PIC

Recommended Maximum

(DSL Assistant Green Zone)

1st segment

15.25 kft.

2nd/3rd segment

15.05 kft.

Attenuation Limits

Recommended Maximum

(DSL Assistant Green Zone)

Upstream

Downstream

1st segment

31 dB

33 dB

2nd/3rd segment

30 dB

30 dB

NOTE: In three segment circuits (two H4Rs), individual

segment resistance values must be verified. Refer
to the HDSL4 Deployment Guidelines section of
the Installation and Maintenance Practice
(P/N 61222404L1-5x) for those guidelines.