ADTRAN 3192 H4TU-C User Manual
ADTRAN Hardware
3192 H4TU-C
1222404L1
DSX
/DS1
ALM
DSL 1
DSL 2
R
S
2
3
2
LBK
ESF
/SF
B8ZS
/AMI
H TUC
TX
RX
TX
RX
DSX MON
DSX EQ
3192 H4TU-C
CLEI: T1L56YSC_ _
LED STATUS
DSL1/DSL2
●
Green
Loop 1/ Loop 2 synchronization achieved and signal is present.
No errors currently detected, and SNR margin
≥
3 dB.
●
Red
Loop 1/ Loop 2 synchronization not achieved, in sync with errors,
or SNR margin < 3 dB.
DSX
●
Green
DSX-1 signal present and no errors currently detected.
●
Red
In framed mode, denotes loss of framing or loss of sync at the
DSX-1 input. In unframed mode, denotes loss of signal DSX-1
input.
ALM
●
●
Off
No T1 alarms are active.
●
Red
Loss of DSX-1 signal from the network.
●
Yellow
Loss of DS1 signal from the CPE.
ESF/SF
●
●
Off
Unit has detected Unframed data.
●
Yellow
Unit has detected ESF framing data.
●
Green
Unit has detected SF framing data.
B8ZS/AMI
●
Yellow
Unit has detected B8ZS line coding data.
●
Green
Unit has detected AMI line coding data.
LBK
●
●
Off
No local loopbacks active.
●
Yellow
Local loopback active.
DSX EQ SPLITTING JACKS
TX
DSX-1 transmit toward the local loop (intrusive)
RX
DSX-1 receive from the local loop (intrusive)
DSX MONITOR JACKS
TX
DSX-1 transmit toward the local loop (nonintrusive)
RX
DSX-1 receive from the local loop (nonintrusive)
COMPLIANCE
WARNING: Up to –200 VDC might be present on telecommunications wiring. Ensure chassis
ground is properly connected. The DSX-1 interface is intended for connection to
intra-building wiring only.
This product is intended for installation in restricted access locations only and in equipment
with a Type “B” or “E” enclosure.
This product provides span powering voltage (negative only with respect to ground, –190 VDC
nominal, GFI protection < 5 mA) and meets all requirements of Bellcore GR-1089-CORE (Class A2),
and ANSI T1.418-2002. This product is NRTL Listed to the applicable UL standards.
POWERING MODE
The H4TU-C provides –190 VDC span powering voltage and will provide powering to the H4Rs
and the H4TU-R. The –190 VDC span powering voltage is provided on Loop 2.
■ For a complete Installation and Maintenance Practice (P/N 61222404L1-5): 877-457-5007, Faxback Document 885. Please have your fax number ready. ■
C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
ut
Code
Input Output
Power Code (PC)
F
C
Telecommunication Code (TC)
–
X
Installation Code (IC)
A
–
1
2
3
4
5
6
7
8
9
10
A
B
C
D
E
F
H
J
K
L
R1 Rx DSX (Out to DSX)
R Tx DSX (In from DSX)
GND
R1 HDSL4 Loop 2
—48V
R HDSL4 Loop 1
T Tx DSX (In from DSX)
T1 Rx DSX (Out to DSX)
RCV LOS (to Alarm Module)
T1 HDSL4 Loop 2
Frame Ground
T HDSL4 Loop 1
Fuse Alarm (to Alarm Module)
H4TU-C EDGE CONNECTOR WIRING
JOB
A
ID
61222404L1-22D
031
1
#61222404L1-22D#
DEFAULT PROVISIONING VALUES
Provisioning Options
Option Settings
Default Settings
1. DSX-1 Line Build Out
0-133 Feet
0-133 Feet
133-266 Feet
266- 399 Feet
399-533 Feet
533-655 Feet
2. DSX-1/DS1 Line Code
AMI, B8ZS
B8ZS
3. DSX-1/DS1 Framing
SF, ESF, Unframed, Auto
ESF
4. Forced Frame Conversion
Enabled, Disabled
Disabled
5. Smartjack Loopback
Enabled, Disabled
Enabled
6. Loopback Timeout
None, 120 Minutes
120 Minutes
7. Latching Loopback Mode
T1 (Disabled), FT1 (Enabled)
T1 (Disabled)
8. DS1 TX Level
0 dB, –7.5 dB, –15 dB
–7.5 dB
9. Span Power
Enabled, Disabled
Enabled
10. Customer Loss Indicator
AIS, AIS/CI, Loopback
AIS/CI
11. PRM Setting
None, SPRM, NPRM, Auto
Auto
12. Loop Atten Alarm Threshold
0 (Disabled)
34 dB
1-99 dB
13. SNR Margin Alarm Threshold 0 (Disabled)
4 dB
1-15 dB
14. Remote Provisioning
Enabled, Disabled
Enabled