beautypg.com

ADTRAN 3192 H4TU-C User Manual

ADTRAN Hardware

background image

3192 H4TU-C

1222404L1

DSX

/DS1

ALM

DSL 1

DSL 2

R
S
2
3
2

LBK

ESF

/SF

B8ZS

/AMI

H TUC

TX

RX

TX

RX

DSX MON

DSX EQ

3192 H4TU-C

CLEI: T1L56YSC_ _

LED STATUS

DSL1/DSL2

Green

Loop 1/ Loop 2 synchronization achieved and signal is present.
No errors currently detected, and SNR margin

3 dB.

Red

Loop 1/ Loop 2 synchronization not achieved, in sync with errors,
or SNR margin < 3 dB.

DSX

Green

DSX-1 signal present and no errors currently detected.

Red

In framed mode, denotes loss of framing or loss of sync at the
DSX-1 input. In unframed mode, denotes loss of signal DSX-1
input.

ALM

Off

No T1 alarms are active.

Red

Loss of DSX-1 signal from the network.

Yellow

Loss of DS1 signal from the CPE.

ESF/SF

Off

Unit has detected Unframed data.

Yellow

Unit has detected ESF framing data.

Green

Unit has detected SF framing data.

B8ZS/AMI

Yellow

Unit has detected B8ZS line coding data.

Green

Unit has detected AMI line coding data.

LBK

Off

No local loopbacks active.

Yellow

Local loopback active.

DSX EQ SPLITTING JACKS

TX

DSX-1 transmit toward the local loop (intrusive)

RX

DSX-1 receive from the local loop (intrusive)

DSX MONITOR JACKS

TX

DSX-1 transmit toward the local loop (nonintrusive)

RX

DSX-1 receive from the local loop (nonintrusive)

COMPLIANCE

WARNING: Up to –200 VDC might be present on telecommunications wiring. Ensure chassis

ground is properly connected. The DSX-1 interface is intended for connection to
intra-building wiring only.

This product is intended for installation in restricted access locations only and in equipment
with a Type “B” or “E” enclosure.

This product provides span powering voltage (negative only with respect to ground, –190 VDC
nominal, GFI protection < 5 mA) and meets all requirements of Bellcore GR-1089-CORE (Class A2),
and ANSI T1.418-2002. This product is NRTL Listed to the applicable UL standards.

POWERING MODE

The H4TU-C provides –190 VDC span powering voltage and will provide powering to the H4Rs
and the H4TU-R. The –190 VDC span powering voltage is provided on Loop 2.

■ For a complete Installation and Maintenance Practice (P/N 61222404L1-5): 877-457-5007, Faxback Document 885. Please have your fax number ready. ■

C A U T I O N

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

ut

Code

Input Output

Power Code (PC)

F

C

Telecommunication Code (TC)

X

Installation Code (IC)

A

1
2
3
4
5
6
7
8
9

10

A
B

C
D

E

F

H

J

K

L

R1 Rx DSX (Out to DSX)

R Tx DSX (In from DSX)

GND
R1 HDSL4 Loop 2

—48V
R HDSL4 Loop 1

T Tx DSX (In from DSX)
T1 Rx DSX (Out to DSX)

RCV LOS (to Alarm Module)

T1 HDSL4 Loop 2

Frame Ground
T HDSL4 Loop 1

Fuse Alarm (to Alarm Module)

H4TU-C EDGE CONNECTOR WIRING

JOB

A

ID

61222404L1-22D

031

1

#61222404L1-22D#

DEFAULT PROVISIONING VALUES

Provisioning Options

Option Settings

Default Settings

1. DSX-1 Line Build Out

0-133 Feet

0-133 Feet

133-266 Feet
266- 399 Feet
399-533 Feet
533-655 Feet

2. DSX-1/DS1 Line Code

AMI, B8ZS

B8ZS

3. DSX-1/DS1 Framing

SF, ESF, Unframed, Auto

ESF

4. Forced Frame Conversion

Enabled, Disabled

Disabled

5. Smartjack Loopback

Enabled, Disabled

Enabled

6. Loopback Timeout

None, 120 Minutes

120 Minutes

7. Latching Loopback Mode

T1 (Disabled), FT1 (Enabled)

T1 (Disabled)

8. DS1 TX Level

0 dB, –7.5 dB, –15 dB

–7.5 dB

9. Span Power

Enabled, Disabled

Enabled

10. Customer Loss Indicator

AIS, AIS/CI, Loopback

AIS/CI

11. PRM Setting

None, SPRM, NPRM, Auto

Auto

12. Loop Atten Alarm Threshold

0 (Disabled)

34 dB

1-99 dB

13. SNR Margin Alarm Threshold 0 (Disabled)

4 dB

1-15 dB

14. Remote Provisioning

Enabled, Disabled

Enabled