beautypg.com

Disable ir receiver from front panel, In the command and response t, Edid minder – Extron Electronics SW DVI Plus Series User Guide User Manual

Page 27

background image

SW DVI Plus Series • Remote Configuration and Control

21

21

21

Command

ASCII Command
(Host to Unit)

Response
(Unit to Host)

Additional Description

EDID Minder

Assign EDID to inputs

E

A *

X%

EDID

}

Edid A

X%

]

Select EDID file

X%

for all inputs.

X%

= EDID file location number (see

below):

0 = Automatic mode (default):
EDID of connected display is
detected and passed to the
inputs.
1 = 800x600 @ 60 Hz

2 = 1024x768 @ 60 Hz (default)

3 = 1280x1024 @ 60 Hz

4 = 1280x800 @ 60 Hz

5 = 1360x768 @ 60 Hz

6 = 1366x768 @ 60 Hz

7 = 1440x900 @ 60 Hz

8 = 1400x1050 @ 60 Hz

9 = 1680x1050 @ 60 Hz

10 = 1600x1200 @ 60 Hz

11 = 1920x1200 @ 60 Hz

12 = 1280x720 @ 60 Hz

13 = 1920x1080 @ 60 Hz

14 = 1280x720 @ 50 Hz

15 = 1920x1080 @ 50 Hz

16 = User-loaded

Example:

E

A*9EDID

}

Edid A 09

]

Select EDID file 9 (1680x1050 @
60 Hz) to be stored at the inputs.

View EDID assignment

E

A * EDID

}

X%

]

Show the number of the EDID file
currently assigned to the inputs.

View EDID in Hex

E

R * EDID

}

X^

]

View the current EDID assignment in
hexadecimal (256 bytes).

X^

= current EDID information in hex.

View EDID native resolution

E

N * EDID

}

X&

]

Show the native resolution

X&

of the

current EDID.

Save display EDID to user location

E

S * EDID

}

Edid S

]

Store the EDID of the connected
display as the user-loaded EDID file
16.

Front Panel Lockout (Executive Mode)

Enable and disable lock mode

X@

X

Exe

X@

]

For

X@

:

1 = front panel locked .

0 = front panel unlocked (default).

View lockout status

X

X@

]

Show lock mode on/off status.

Disable IR Receiver from Front Panel

Enable and disable IR receiver

X@

* 65 #

IRDisable

X@

]

Disable the IR remote receiver on the
front panel from receiving signals
from the IR remote control.

View IR disable status

65 #

X@

]

View IR receiver status. For

X@

:

0 = IR Disable feature is off (IR is
enabled) (default).
1 = IR Disable feature is on (IR is

disabled).