Advanced setup menu, Screen saver timer submenu (scrsvr timer), Power off timer submenu (pwroff timer) – Extron Electronics VTG 300_300R User Guide Rev. E User Manual
Page 16
Advanced Setup Menu
The following flowchart provides an overview of the Advanced Setup menu.
Extron
VTG 300R
ADVANCED
SETUP
MENU
NEXT
PwrOff Timer
15 min
NEXT
NEXT
ScrSvr Timer
Disabled
NEXT
NEXT
NEXT
Enable@PwrUp
Last Used
Press & Hold
& to reset
Power Off Timer
• Disabled
• 5 minutes
• 15 minutes (default)
• 30 minutes
Screen Saver Timer
• Disabled (default)
• 5 minutes
• 10 minutes
• 15 minutes
Enable Outputs at Power Up
• Last Used (default)
• Vid Only
• Aud Only
• Aud+Vid
Unit Reset
• Simultaneously press and
hold any of the three and
button pairs for two seconds
to reset the VTG to factory
default settings.
ScrSvr Mode
CYCLE
Select Screen Saver
• Blank - black screen
• Cycle - cycles through all
six test pattern categories
Figure 7.
Advanced Setup Menu
Power off timer submenu (PwrOff Timer)
When enabled, this feature allows the VTG to be automatically powered off after a certain
period of button inactivity has elapsed. This power off feature conserves battery power.
NOTE: When the VTG is powered by the external power supply, this power off feature is
disabled.
Press any or button to select from among the power off timer options:
•
Disable - disable this timer feature
•
5-minute power off time out
•
15-minute power off time out (default)
•
30-minute power off time out
Screen saver timer submenu (ScrSvr Timer)
This feature protects against CRT/plasma burn-in. When enabled, this feature allows the
VTG to set the screen saver inactivity timer. This timer will activate the screen saver after the
selected timer interval has elapsed without any button being pressed. See the Screen saver
mode submenu (ScrSvr) description in this chapter for selecting a screen saver display.
Press any or button to select from among the screen saver timer options:
•
Disable - disable this timer feature (default)
•
5-minute screen saver time out
•
10-minute screen saver time out
•
15-minute screen saver time out
Selecting any of the time outs will result in a modified default menu cycle, as shown in
. While timed out, pressing any front panel button will cancel (disable) the time out.
VTG 300/300R • Operation
10