beautypg.com

Extron Electronics VTR001 User Guide User Manual

Page 19

background image

AAP mounting

The VTR001 AAP version is mounted to the Extron AAP panel by inserting the two AAP
studs through the panel mounting holes and attaching the nuts, as shown below.

VTT001CM AAP Install.eps

Cable

Cable
Clamp

VTR001 AAP

AAP 102

AAP 102

#4-40 Nut w/ Captive
Washer

VTR001 AAP

VIDEO IN

PU

T

Figure 10.

Attaching a VTR001 AAP to an Extron AAP Frame

Rack mounting

UL rack mounting guidelines

The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the
device in a rack.

1.

Elevated operating ambient temperature — If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater
than room ambient temperature. Therefore, install the unit in an environment compatible
with the maximum ambient temperature (Tma = +122 °F, +50 °C) specified by Extron.

2.

Reduced air flow — Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is not compromised.

3.

Mechanical loading — Mount the equipment in the rack so that a hazardous condition
is not achieved due to uneven mechanical loading.

4.

Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.

5.

Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (that is, use of power strips).

VTT001 and VTR001 User Guide • Installation

14

This manual is related to the following products: