39 avi recommended exhaust flow rates – XLT XD-9005B User Manual
Page 39

Technical Support US: 888-443-2751
Technical Support INTL: 316-943-2751
39
AVI RECOMMENDED EXHAUST FLOW RATES
The VELOCITY readings above are obtained by holding an anemometer 3” away from the Grease
Filter. Take several readings in different locations across the filters and average the results.
NOTE
Most building codes require 500 Feet per Minute velocity. Exhaust duct is 1 ft
2
.
Check with your local building official for requirements.
Top Middle Bottom
187.5
187.5
93.75
93.75
[57.15]
[57.15]
[28.58]
[28.58]
187.5
187.5
93.75
93.75
[57.15]
[57.15]
[28.58]
[28.58]
189.75
241.5
155.25
181.125
[57.84]
[73.61]
[47.32]
[55.21]
189.75
241.5
155.25
181.125
[57.84]
[73.61]
[47.32]
[55.21]
187.5
187.5
93.75
93.75
[57.15]
[57.15]
[28.58]
[28.58]
189.75
241.5
155.25
181.125
[57.84]
[73.61]
[47.32]
[55.21]
287.25
365.625
235.125
274.3125
[87.55]
[111.44]
[71.67]
[83.61]
189.75
241.5
155.25
181.125
[57.84]
[73.61]
[47.32]
[55.21]
287.25
365.625
235.125
274.3125
[87.55]
[111.44]
[71.67]
[83.61]
287.25
365.625
235.125
274.3125
[87.55]
[111.44]
[71.67]
[83.61]
287.25
365.625
235.125
274.3125
[87.55]
[111.44]
[71.67]
[83.61]
Switches On
18xx
24xx
32xx
38xx
Single
X
Exhaust Flow Rates VELOCITY (min. recommended)
Double
X
X
X
X
Triple
X
X
X
X
X
X
X
X
X
X
X
X
NOTE
All values are FPM [M/Min] unless otherwise noted. Figures represent VELOCITY
measured at the Grease Filter.