19
Table 1-3. Supplemental Characteristics (continued)
High Line Inrush Current:
100 V Opt
120 V Opt
220 V Opt
240 V Opt
Peak Value
85 A
85 A
50 A
50 A
rms Value
6.3A
5.7 A
3.0 A
3.0 A
Fuse Rating
8 A
8 A
4 A
4 A
GP-IB Interface Capabilities:
SH1. AH1, T6, L4, SR1, RL1, PP1, DC1, DT0, C0, E1
Current Sink Capability:
25 Watt output: 0.50 A
50 Watt output: 1.0 A (2.0 A below 16 V)
Command Processing Time:
(see Figure 1-3)
7 milliseconds typical (with front panel disabled). Using STD and RCL commands allows you to change all the
voltage and current settings in about 10 mS (with front panel disabled).
Maximum Output Programming:
Response Time
6 mS
6 mS
6 mS
6 mS
Settling Band
50 mV
50 mV
50 mV
50 mV
Maximum Time
Constant
750
µ
S
750
µ
S
750
µ
S
750
µ
S
Series and Parallel operation:
Two outputs can be operated directly in parallel or can be connected for straight series operation. Refer to Chapter 4
for more information.
Reactive Load Capability:
All outputs have been designed with the ability to operate with significant reactive loads without instability (refer to
Figures 1-4 through 1-6)
Safety Agency Compliance:
This series of power supplies is designed to comply with the following standards:
IEC 348, UL 1244, and CSA 22.2 No. 231.
Dimensions (all models):
Height
132.6mm (5.22 in)
Width
425.5mm (16.75 in.)
Depth
497.8mm (19.6 in.)