beautypg.com

Programming power supply registers, Programming power supply registers present status – Agilent Technologies 6625A User Manual

Page 105

background image

Programming with a Series 200/300 Computer

105

10 ASSIGN @Ps TO 705
20 OUTPUT @Ps;’’VSET?1’’
30 ENTER @Ps;Vsl
40 OUTPUT @Ps;"ISET?1"
50 ENTER @Ps;Isl
60 PRINT ’’VOLTAGE SETTING OF OUTPUT #1 = ";Vsl
70 PRINT "CURRENT LIMIT SETTING OF OUTPUT #1 = ";Isl
80 END

Line 10:

Assigns the I/O pathname to the power supply.

Line 20,30:

Queries the supply for output 1’s voltage setting. You cannot string multiple queries together in a single
device command because the power supply can only return the most recently queried data.

Line 40,50:

Queries the supply for output 1’s current limit.

Line 60,70:

Prints the results of the queries on the screen.

Programming Power Supply Registers

Present Status

The power supply makes available several forms of status information. Chapter 5 discusses the different registers and their
functions. The present status register contains continuously updated information. The following example shows how to
query bit position 0 of output 1’s status register to see if output 1 is in CV mode. In this example, the program references the
function as a variable in a conditional execution statement. Note that instead of printing a message, line 30 could be used to
branch to another part of the program in the event that the supply is in CV mode.

10 ASSIGN @Ps TO 705
20 COM /Ps/ @Ps
30 IF FNCv _ mode THEN
40 PRINT "OUTPUT 1 IS IN CV MODE"
50 END IF
60 END
70 !
80 !
90 DEF FNCv _ mode
100 COM /Ps/ @Ps
110 OUTPUT @Ps;’’STS?1"
120 ENTER @Ps;Sts
130 RETURN BIT(Sts,0)
140 FNEND

Line 10:

Assigns the I/O path name to the power supply.

Line 20:

Declares a common block for the I/O path name. The COM statement must be used for the @Ps variable
to preserve its value in the function subprogram.

Line 30,40,50:

If FNCv _ mode is true, print the message.

Line 90:

Defines the Cv _ mode function.

Line 100:

Brings in the common block for the I/O pathname.

Line 110,120:

Reads the present status of output 1 into the variable Sts.

Line 130:

Returns the value of bit position 0 of Sts.