Warner Electric MCS-131 User Manual
Page 9
CH 2
CH 1
ON
ON
ON
ON
OUTPUTS
SWITCHING SIGNALS
START
SCANNER
SCANNER
INHIBIT
STOP
6040-448-016 SWITCH PROGRAMMING
Open: The
output f.f. goes low, ligic “0” at the negative transition
of the “stop” inut. It may be immediately retriggered.
Closed: The
output f.f. goes low, ligic “0” at the negative transiotion
of the “stop” input and remains low as long as this
input is low.
Open: The
scanner input must be low, logic “0”, and go hight,
Closed: logic “1” when a mark is detected.
Closed: the scanner input must be high, logic “1”, and go low,
Open: logic
“0” when a mark is detected.
Open: The
output f.f. trips high, logic “1” at the negative
transition of the “start” input.
Closed: The
information in the output f.f. remains latched after the
negative going transition of the “start” input.
SW 1
SW 2*
SW 3*
SW 2*
SW 3*
SW 4
* Only one of the two switches may be closed.
OPTIONAL LOGIC BOARD 6040-448-017
MCS-131
START
INH
CH 1
CH 2
STOP
N.C.
CH1
CH2
LED
+12V
DC
COM
EARTH
GND
AC
INPUT
+
+
-
-
DC
COM
+24V
+4.8V
18
17
16
120 VAC
OR
240 VAC
15
14
13 12
11
10
9
8
7
6
5
4
3
2
1
S2
S3
S1
SWITCHING
S1 - START INPUT SWITCH
S2 - STOP INPUT SWITCH
S3 - INHIBIT INPUT SWITCH
NOTE: SWITCHING LOGIC DEPENDENT ON SWITCH
SETTINGS ON LOGIC BOARD 6040-448-017
TERMINAL DESIGNATIONS
1. START INPUT
2 INHIBIT
3 +
4 -
5 -
6 +
7 STOP INPUT
8 NO. CONNECTION
9 LED CHANNEL 1
10 LED CHANNEL 2
11 +12 VDC @ 100 MA.
12 DC COMMON
13 EARTH GROUND
14 -
15 -
16 +4.8 VDC OUTPUT (Optional Board)
17 DC COMMON
18 +24 VDC OUTPUT
CHANNEL 1 OUTPUT
CHANNEL 2 OUTPUT
AC INPUT
Figure 5 - Input - Output Switching Relationships with Logic Board 6040-448-018
Figure 6 - Extended Input Switching With Logic Board 6040-448-017