B. Switch Logic Module, 6040-448-017
This module expands the input capabilities of the basic MCS-131 Control. For most application, however, the
Bag Logic Module, 6040-448-016, will be used.
Switch No.
Function Affected
Control Operation
1
Always Closed
----------
2
Input Signals
Open: Pulse Control
Closed: Level Control
3
Not Used
4
Always Closed
----------
Using the Stitch Logic Board, 6040-448-017, switching inputs change somewhat from the basic MCS-131
Control. Input switching configurations are shown in Figure 6.
Terminal No.
Function
Control Input Logic
1
Start
Pulse or Level
2
Inhibit
Level only, Active Low
7
Stop
Pulse or Level
For waveform timing diagram, see Figure 7.
Cautions
Fusing:
For 120 VAC operation a 1.6A slo-blo fuse should be used.
for 240 VAC operation a 1.0A slo-blo fuse should be used.
Note: When replacing a fuse, the same type and size as specified should be used to prevent
control damage.
AC:
AC line voltages are present at the terminal strip.
Warner Electric • 800-825-9050
P-262 • 819-0493