Interface Programming
The two optional logic modules provide for expanded input switching of the basic control. Logic board
selection will be dependent primarily upon the input switching requirements. For most applications, the
bag logic module will be the more suitable.
Board Set Up and Programming
A. Bag Logic Board, 6040-448-016
Switch No.
Function Affected
Control Operation
SW 1
Stop
Open: Pulse Control on terminal 7. Triggers on negative
transition of input pulse.
SW 2
Photo Input
Closed: Dark Operation, switches
SW 3
Open: On negative transition
SW2
Photo Input
Open: light Operation, switches
SW 3
Closed: On positive transition
SW4
Start
Open: Pulse Control on terminal 1. Triggers on negative
transition of input pulse.
Closed: Level input on terminal 1. Active low, triggers on
negative transition of input.
Using the Bag Logic Module, 6040-448-016, control input terminal designations change somewhat as
shown in Figures 3 and 4.
Terminal No.
Function
Control Input Logic
1
Start
Selectable on Card for Level or Pulse
2
Photo Inhibit
Level only, Active Low
7
Stop
Selectable on Card for Level or Pulse
8
Photo Input
Level, Light/Dark Card Selectable
For waveform timing diagrams, see Figure 5.
Warner Electric • 800-825-9050
P-262 • 819-0493
4