Maintenance and repair

T

ROUBLESHOOTING

G

UIDE

--

______

Warning: Before performing any task, always block drive wheel off of the ground.
Consult the factory for problems at time of installation, or for any problems not addressed below.




Problem:

Possible cause(s):

Action:

Unit will not charge


Charger malfunction




Bad batteries

Verify output voltage on charger,

will only get a reading when
connected to batteries; should be
approximately 28 volts.


Load test batteries

Unit will not raise; motor does not

run

Loose wire






Bad solenoid







Upper limit switch out of

adjustment



Blown fuse

Batteries discharged

Verify 24 volts at coil when

raise is pushed, if no
voltage; trace wiring
back to till her head
looking for voltage on
each side of the
connectors until the bad
connection is found.


If voltage is present at the solenoid

and the unit does not rise, remove
the two wires to the coil and
measure the coil resistance. It
should be around 19 ohms. If it’s
open, or shorted replace the
solenoid.


Bypass upper limit switch and see if

the unit raises…DO NOT TAKE IT
ALL THE WAY UP… If it does rise,
verify the limit switch is normally
closed and will open when
activated. If the limit switch is ok,
try to adjust the switch
accordingly so that the units raise
height is approximately 7 to 8”


Check fuses above motor controller

Re-charge batteries

Unit will not raise; motor runs

Lower solenoid stuck on





No hydraulic oil

Check to see if the lowering switch is
stuck on. If it is, remove the tiller
head via 3 screws on bottom and
replace switch, or tap on switch to
see if it can be freed up.

Re-fill hydraulic oil

Unit will not lower




Loose wire; bad coil






Verify 24 volts at coil when lower is

pushed, if no voltage, trace wiring
back to tiller head looking for
voltage on each side of the
connectors until the bad
connection is found.


If voltage is present at the coil and