Listing Label

The safety (listing) label is attached to the operating tag (chained to the fireplace near the gas
control valve). A copy is shown below

Bed & Breakfast

V

ented Gas

Fireplace Heater

Report No. 028-S-53-5

Certified for USA

Tested to:

ANSI Z21.88b-2001 “V

ented Gas Fireplace Heater” and UL

307b-1995 “Gas Burning Heating

Appliances

for Manufactured Homes”.

VENTED GAS FIREPLACE HEA

TER – NOT FOR USE WITH SOLID FUEL

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,

ANSI Z223.1.

This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is

desired, the optional factory conversion kit must be used.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,

permanently located, manufactured (mobile) home where not prohibited by local codes. See owner

’s manual for

details. This appliance is not convertible for use with other gases, unless a certified kit is used.

This vented gas fireplace heater is not for use with air filters.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

W

ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property

damage. Refer to the owner

’s information manual provided with this appliance. For assistance or additional

information consult a qualified installer

, service agency or the gas supplier

.

W

ARNING: Operation of this appliance when not connected to a properly installed and maintained venting

system or tampering with the blocked vent shutoff system can result in carbon monoxide (CO) poisoning and

possible death.

CAUTION: Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s)

should be done by a licensed or qualified service person.

CAUTION: Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids

having flammable vapors away

.

This appliance must be properly connected to a venting system in accordance with the manufacturer

’s installation

instructions. Use only approved coaxial direct vent system to vent this appliance to the exterior

. See owner

’s

manual for approved brands of venting.

10850 1

17th Pl. N.E. Kirkland, W

A

98033

Minimum Clearances to Combustibles

Stove to Side, Back and T

op
..............

1/2”

Decorative Front to W

ood Facing

...........

1/8”

Stove to Bottom

..................................

0”

Decorative Front to 12” Deep Mantle

......

8”

Decorative Front to Sidewall

...................

1/2”

L.P
.

N.G.

L.P
.
N.G.

Input Rate on “HI” (BTU/Hr) . . . . . . .

16,500

16,500

Minimum Inlet Pressure (inches W

.C.)

. . . . . . . .

11”

5.5”

Input Rate on “LO” (BTU/Hr)

. . . . . .

13,400

14,500

Manifold Pressure on “HI” (inches W

.C.)

. . . . . .

10”

3.5”

This appliance is equipped only for altitudes 0-2000 ft. (0-610 m).

Electrical Rating:

115v
, 1.5

Amps, 60 Hz

Manufacture

2002

Jan.

Apr
.

Jul.

Oct.

Date: